19
EN
DISPLAY INFORMATION IN STAND-BY MODE
In stand-by mode the upper line of the display shows the system status.
The informations are displayed in the following order of priority:
MAINTENANCE
maintenance by the installator. In this case no intrusion
alarm nor tamper alarm will go off.
TAMPER
tamper condition on at least one of the partitions enabled
for the keypad
ALARM!
an alarm is active on at least one of the partitions enabled
for the keypad
MISSING PERIPH. at least one KS-BUS peripheral is missing
TAMPER
MEMORY
tamper memory on at least one of the partitions enabled for
the keypad
ALARM MEMORY
alarm memory on at least one of the partitions enabled for
the keypad
SYSTEM FAULTS the system has at least one fault
FAULT MEMORY there is a fault in memory
ENTRY TIME
entry time is active on at least one of the partitions enabled
for the keypad
EXIT TIME
exit time is active on at least one of the partitions enabled
for the keypad
WARNING TIME
warning time is active on the partitions enabled for the
keypad
PHONE CALL
ACTIVE
a telephone call is in progress
USB
CONNECTION
the panel is connected to the pc by USB port or a fl ash USB
key is connected to the panel
REMOTE ASS. remote assistancee is enable on the panel
ZONE BYP/TEST at least one zone is in test or manually bypassed
REMOTE
LISTENING
the remote listening from the keypad microphone is active
SYSTEM OK there are no faults