A IR QUALITY MONITOR
Instructions man ual
INTRODUCTION:
Congratulations on purchasing this Air Quality Monitor with wireless
868 MHz transmission of outdoor temperature and display of indoor
temperature/humidity, and time. With only four easy to use function
keys, this innovative product is ideal for use in the hom e or office.
FEATURES:
AIR QUALITY MONI TOR
12/24h time display
Temperature display in ºC / ºF
Indoor and outdoor temperature display with M IN/MAX records
Indoor humidity display in RH%
Air quality alert
Air quality indicator
Low battery indicator
THE OUTDOOR TEM PERATURE TRANSMITTER
Remote transmission of outdoor
temperature to the air quality monitor
by 868 MHz signal
Rain proof casing
Wall mounting case
TO INSTALL AND REP LACE B ATTERIES IN THE
TEMPERATURE TR ANSMITTER
The temperature transmitter uses 2 x AA, IEC,
LR6, 1.5V batteries. To install and replace the
batteries, please follow the steps below:
1. Remove the cover.
2. Insert the batteries, observing the
correct polarity (see marking).
3. Replace the battery cover on the unit.
TO INSTALL AND REP LACE B ATTERIES IN THE AIR
QUALITY MONIT OR
The air quality monitor uses 2 x C, IEC LR14, 1.5V battery. To install
and replace the battery, please follow the steps below:
1. Remove the cover at the back of the air quality monitor.
2. Insert batteries observing the correct polarity (see m arking).
3. Replace compartment cover.
SETTING UP:
1. First, insert the batteries in the transmitter (see “Install and
replace batteries in the temperature transmitter” above).
2. Within 2 minutes of powering up the transmitter, insert the
batteries in the Temperature Station (see “Install and replace
batteries in the air quality monitor” above).
3. The indoor temperature/humidity and the time as 0:00 will be
displayed. If these information are not displayed on the LCD
after 60 seconds, remove the batteries and wait for at least 60
seconds before reinserting them. Once the indoor data is
displayed user may proceed to the next step.
4. The air quality monitor will start receiving data signal from the
transmitter. The outdoor temperature data should then be
displayed on the air quality monitor. If this does not happen
after 2 minutes, the batteries will need to be removed from both
units and reset from step 1
Note:
The Equivalent CO
2
ppm will only be displayed after 30
minutes.
The air quality sensor will take up to 5 days after inserting
batteries to condition itself for the room it is placed. If the unit is
placed into another room, there might be a reconditioning time
of several days as well.
BATTERY CHAN GE:
It is recommended to replace the batteries in the unit regularly to
ensure optimum accuracy of the unit (Battery life See Specifications
below).
Please participate in the preservation of the
environment. Return used batteries to an authorised
depot.
KEY FUNCTIONS:
The Air Quality Monitor has 4 easy-to -use keys:
SET key:
Press and hold to enter the manual setting m odes: 12 /24 hour
time display, manual time, and ºC / ºF temperature display
settings
+ key:
Press to change, set, toggle all manual settings
AL key:
Stop the LED air quality alert
Exit the manual setting mode
MIN/MAX key:
Press to toggle between MAX/MIN and current indoor
temperature/humidity and outdoor data
Exit the manual setting mode
LCD SCREEN
* When the signal is successfully received by the temperature station,
the outdoor transmission icon will be switched on. (If not successfu l,
the icon will not be shown on LCD). The user can then easily see
whether the last reception was successful (icon on) or not (icon off).
On the other hand, the short blinking of the icon shows that a
reception is currently taking place.
MANUAL SETTINGS :
The following manual settings can be done in the setting mode:
12/24 hour time setting
Time setting
ºC / ºF temperature display setting
Press and hold the SET button for about 3 second to enter the setting
mode:
12/24 HOUR TIME DIS PL AY SETTING
1. “12hr” or “24hr” flashes in the LCD. (default 24hr)
2. Press the + key to select the “12hr” or “24hr” display mode.
3. Confirm with the SET key and enter the Manual time setting .
MANUAL TIME SE TTING
To set the clock:
1. The hour digits start flashing in the time display section.
2. Use the + key to adjust the hours and the n press SET key to go
to the minute setting.
3. The minute will be flashing. Press the + key to just the minutes.
4. Confirm with the SET key and enter the °C/°F temperature
unit setting.
°C/°F TEMPERATURE UNIT SE TTING
The default temperature reading is set to °C (degree Celsius). To
select °F (degree Fahrenheit):
1. The “°C” will be flashing, use the + key to toggle between “°C”
and “°F”.
2. Confirm with the SET key and exit the manual settings .
AIR QUALITY ALERT:
The LED will flash when:
Equivalent CO
2
ppm
> 1500ppm:
LED alert blinks at a slower speed (1.5s).
Equivalent CO
2
ppm
> 2000ppm:
LED alert blinks at faster speed (0.5s).
Note about the air quality alert:
The air quality alert will sound for a maximum duration of 30
minutes.
To stop the alert, press any key.
AIR QUALITY IND ICATOR
The air quality indicator is located on the bottom of the LCD. It
changes from GREEN (GOOD) to RED (BAD ) by measuring the
Equivalent CO
2
ppm.
* The air quality value shown, after sensor conditioning, may differ +/-
250 ppm.
Note:
A 9-level bar graph is used to indicate “GREEN” to “RED” air quality
level in the surrounding environment:
DISPLAY OF MIN/M AX TEMPERA TURE AND HUMI DITY
RECORDS:
1. In normal display mode, press the MIN/MAX key once. The
MIN indoor/outdoor temperature and indoor hum idity will be
shown in the LCD.
2. Then press the MIN/MAX key one more time, the MAX
indoor/outdoor temperature and indoor humidity will be shown
in the LCD.
3. Press one more time the MIN/MAX key to go back to the
normal display.
RESETTING THE IND OOR MAXIMUM / MINIM UM
RECORDS
Note: The indoor/outdoor minimum and maximum and humidity
records will be reset at the same time
1. Press and hold the MIN/MAX key for about 3 seconds, this will
reset the indoor/outdoor MIN/MAX temperatures and humidity
to the current temperature and humidity.
TEMPERATURE TR ANSMITTER
The outdoor temperature is measured and transm itted every 4
seconds.
The range of the temperature transm itter may be affe cted by the
temperature. At cold temperatures the transmitting distance may be
decreased. Please bear this in mind when placing the transm itter.
868 MHz RECEPTI ON:
If the outdoor data are not being received within three m inutes after
setting up (or outdoor display always show “- -. - ” in the outdoor
sections of the temperature station during norm al operation), please
check the following points:
1. The distance of the air quality monitor or transm itter should be
at least 2 meters away from any interfering sources such as
computer monitors or TV sets.
2. Av oid placing the transmitters onto or in the immediate
proximity of metal window fram es.
3. Using other electrical products such as headphones or
speakers operating on the 868MHz-signal frequency may
prevent correct signal transmission or reception. Neighbors
using electrical devices operating on the 868MHz-signal
frequency can also cause interference.
Note:
When the 868MHz signal is received correctly, do not re-open the
battery covers of either the transmitter or air quality monitor , as the
batteries may spring free from the contacts and force a false reset.
Should this happen accidentally then reset all units (see Setting up
above) otherwise transmission problems m ay occur.
The transmission range is about 100 m from the tran smitter to the air
quality monitor (in open space). However, this depends on the
surrounding environment and interference levels. If no reception is
possible despite the observation of these factors, all system units
have to be reset (see Setting up ).
Low battery icon (air quality monitor)
Indoor
temperature
in ºC/ºF
Equivalent CO
2
ppm display
Indoor relative
humidity % RH
Outdoor reception
signal*
Low battery
indicator
(transmitter)
Equivalent CO
2
ppm (parts per
million) value*