ENGLISH
distribution of heat through the ventilation
during installation, it is necessary to establish the type of ventilation or convection to be adopted.
ventilation of the installation room
Our products are equipped with series tangential fans suitable to improve the distribution of heat through the ventilation exclusively
of the installation room (see Picture 10 - 11- 13).
ventilation of the adJacent local
The covering of each product is equipped with outputs for the connection of pipes resistant to heat.
a) Perform the drilling on the walls or on the existing hood to allow the passage and the application of the (re-resistant) hoses with related
openings.
b) Fasten the pipes by means of clamps to the related collars and openings, after having removed the semi-blanks caps (see Picture 10 -A).
c) Each pipe must not exceed 1.5 m of length for natural ventilation; it must be insulated with insulating materials to avoid noise and
dispersion of heat.
d) The openings have to be positioned at a height not lower than 2 m from the oor to avoid that hot air at output meets people. Please respect
the distance of the convection openings according to the local construction norms;
e) The lengths of the canalization pipes must have the same length to avoid the distribution of diering quantities of air from each output (see
Picture 10).
f) If the space between the upper part of the insert and the lower prole of the hood is lower than 10 cm, it is necessary to perform a hole of
about 30 x 40 cm on the hood to allow the fastening of the hoses;
connection and maintenance of ventilation
the control unit and the plant must be installed and connected by authorized personnel according
to the standards in forcesee chapter WARNINGS - chapter GENERAL PRECAUTIONS.
attention: the control unit and the feeding cable must not be in contact with hot parts. in any case,
the power cable has to be replaced by authorised personnel only ENTITLED BY LA NORDICA: authorised
dealers and/or fitter.
Our products are equipped with tangential fans suitable to improve the distribution of heat (see chapter DISTRIBUTION OF HEAT THROUGH
THE VENTILATION).
The lighting and the adjustment is carried out through the proper standard supplied control unit that has to be installed far from any direct
heat source.
connection: Connect the power supply cable of the control unit to a bipolar switch respecting at least a 3 mm distance between the
contacts (power supply 230 V~ 50 Hz, it is necessary to provide for the correct connection to the grounding plant).
this operation must be done without electric energy!!
warning: THE COMMAND MUST BE CONNECTED TO THE MAINS WITH A DIFFERENTIAL LINE CUTOFF SWITCH ACCORDING
TO THE REGULATIONS IN FORCE. CORRECT OPERATION OF THE COMMAND IS ASSURED ONLY FOR THE PROPER MOTOR FOR
WHICH IT HAS BEEN MANUFACTURED. improper use relieves the manufacturer from each responsibility.
3131
31

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Nordica INSERTO 80 HIGH PRESSURE wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info