696288
23
Zoom out
Zoom in
Vorherige Seite
1/96
Nächste Seite
ENGLISH
TECHNICAL DESCRIPTION
The appliance is made up of a steel chamber completely soldered and hermetic. The hearth is coated by single cast-iron sheets and refractory
plates (NORDIKER).The appliances are equipped with an integrated air circuit for the recovery of the heat made up of a galvanized steel carter
external to the heating body. Inside the hearth there are a grate holder and the related grating, both made of very thick cast-iron and easily
extractable. The appliance works as an intermittent operating appliance.
The insert is equipped with a sight door with ceramic glass (resistant up to 700°C). This allows a charming sight on burning ames. Moreover,
in this way, any possible leak of sparks and smoke is avoided. Under the hearth grating there is a easily extractable ash drawer.
ACCESSORIES
POKER GLOVE
Ventilation KIT 1318000
SECONDARY air KIT
INSERTO 50 Crystal SERIES SERIES / 6016040 OPTIONAL
INSERTO 50V Crystal BII SERIES SERIES / 6016040 OPTIONAL
INSERTO 50V p30 Crystal SERIES SERIES / 6016040 SERIES
INSERTO 70 Crystal SERIES SERIES * OPTIONAL 6016041 OPTIONAL
INSERTO 80 Crystal EVO 2.0 SERIES SERIES * OPTIONAL 6016041 OPTIONAL
INSERTO 80 Crystal PRS SERIES SERIES * OPTIONAL 6016041 OPTIONAL
INSERTO 100 Crystal SERIES SERIES * OPTIONAL 6016041 OPTIONAL
* see instructions manual CONNECTION AND MAINTENANCE OF VENTILATION OPTIONAL.
The heating of the room occurs:
a) by convection: the passage of air through the coating and the covering hood releases heat in the room.
b) by radiation: through the sight glass and the steel body, heat is radiated into the room.
The device is equipped with registers of primary and secondary air, with which it is possible to adjust the combustion air.
1A - PRIMARY air register (Picture 8)
With the air register located under the door of the hearth (on the left), it is possible to adjust the air ow through the ash drawer and the
grating in direction of the fuel. The primary air is necessary for the combustion process during the ignition. In order to open the passage of
primary air the lever should be completely pulled.
The ash drawer has to be emptied regularly, so that ash cannot hinder the intake of primary air for the combustion. Primary air is also
necessary to keep re live.
During the combustion of wood, the primary air register must be opened only a few, since otherwise the wood burns quickly and the
device can overheat (see chapter NORMAL OPERATION).
2A - SECONDARY air register (Picture 83)
Under the door of the hearth (on the right) there is the secondary air register.
This register must be opened (and therefore the lever completely pushed), in detail, for the combustion of wood, so that unburnt carbon
can be subject to a post-combustion, increasing the yield and assuring the cleaning of the glass (see chapter NORMAL OPERATION). It is
possible to get the air SECONDARY directly from outside through a exible tube (reproof NOT furnished Picture 11 Ref A).
The adjustment of the registers necessary to reach the rated caloric yield is the following one:
INSERTO
50 Crystal
INSERTO
50v Crystal
BII
INSERTO
50v p30
Crystal
INSERTO
70 Crystal
INSERTO
80 Cry EVO
2.0
INSERTO
80 Cry PRS
INSERTO
100 Crystal
Hourly consumption
( kg/h )
1,8 2,4 1,7 2,7 2,1 2,2 2,8
PRIMARY AIR CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED CLOSED
SECONDARY AIR OPENED OPENED OPENED OPENED OPENED OPENED OPENED
TERTIARY AIR
PRE-
ADJUSTED
PRE-
ADJUSTED
PRE-
ADJUSTED
PRE-
ADJUSTED
PRE-
ADJUSTED
PRE-
ADJUSTED
NO
FLUE
Essential requirements for a correct operation of the device:
the internal section must be preferably circular;
be thermally insulated and water-proof and produced with materials suitable to resist to heat, combustion products and
possible condensates;
not be throttled and show a vertical arrangement with deviations not greater than 45°;
if already used, it must be clean;
all the sections of the ue gas duct must be accessible to inspection;
inspection openings must be provided for cleaning.
observe the technical data of the instructions manual;
Should the ues have a square or rectangular section, internal edges must be rounded with a radius not lower than 20 mm. For the rectangular
section, the maximum ratio between the sides must be = 1.5.
A too small section causes a decrease of the draught. It is suggested a minimum height of 4 m.
23
23

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Nordica Inserto Crystal 50V P30 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info