CHIMNEY POT
Flue draught also depends on the suitability of the chimney pot.
chimney pots must meet the following requirements:
1. have a useful output section of more than double the length of the replace/pipe system into which it is inserted
2. be compliant in order to prevent rain and snow from penetrating into the replace/pipe system
3. be constructed in such a way that even in the case of winds from all directions and with any inclination, evacuation of combustion
products (windshield terminal) is ensured.
Installation, relative system connections, commissioning and verication of correct operation must be carried out correctly by professionally
qualied and trained personnel in full compliance with current national, regional, provincial and municipality regulations in the country
where the appliance is installed.
ELECTRICAL CONNECTIONS
Output potential free contact
Puer probe
Smoke probe
Circulator output
Smoke suction fan motor
Fuse 3,15 A
Boiler power supply 230 V / 50 Hz
BOILER CONNECTION TO THE MAINS POWER SUPPLY
The boiler is supplied with a power supply cable (plug NOT supplied) to be connected to a 230V 50 Hz outlet, possibly with a circuit breaker.
The power supply outlet must be easily accessed. The electrical system must be compliant; in particular, check eciency of the earthing
circuit. Improper system earthing can cause malfunctions, which the manufacturer is not liable for. Power variations greater than 10% can
cause product malfunctions.
The product must be installed and connected by qualied personnel in compliance with current regulations. (See Chap. SPECIAL
WARNINGS).
NORDICA S.p.A. shall not be held liable for unauthorised product modications as well as use of non-original spare parts.
WARNING: the boiler must be connected to the mains with an upstream differential line cut-off switch according to the
regulations in force. Connect the power supply cable of the boiler to a bipolar switch with minimum distance between
contacts of 3mm (Power supply 230 V~ 50 Hz; correct system earthing is essential).
The power supply cable must be checked regularly and kept in its original status. Any type of intervention on the safety circuits and
single elements is forbidden so as not to compromise safe and reliable operation of the boiler. In the event of damage to the electrical
system, decommission the boiler, disconnect it from the power supply and ensure professional repair is carried out in compliance with
legal regulations.
ATTENTION, the power supply cable must NOT come into contact with hot parts.
48
48

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für La Nordica LNK15 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info