Dosseret
◊ Use of the rear splash plate :
This feature is particularly recommended for built-in ovens as it ensures a 50 mm gap between the
appliance and the wall. It also increases the depth of the hob to 722,5 mm.
It also enables you to use the parts more easily :
Ref. LDS 1500.
A shut-off valve must be installed and accessible close to the appliance in order to isolate it from
the supply or to facilitate cutting the gas supply :
- Natural gas supply :
Mandatory to install an Automatic Shut-off Valve (since 1st July 1997 in France)
- Alimentation en GPL (Butane – Propane)
Propane : Class 1 Safety Expansion Valve.
Butane : Butane safety expansion valve tted to the cylinder (connected to the range by a LPG
approved hose, maximum length 2 metres).
SITTING