INSTALLER’S MANUAL
Appliances must be installed in a workmanlike manner in accordance with the instructions in
this manual and locally applicable regulations. This manual will be handed over to the user after
installation.
Before connection, check :
ü That the electrical supply of the system is compatible with the voltage and power of the range.
ü That the user’s xed installation includes an approved all-pole cut-out device.
Connection : ATTENTION :
- Cable insulation must be type 245 IEC 57 or 245 IEC 66
- The wires in the power supply cable between the anti-tugging device and the terminals must be
long enough to enable the live wires to extend before the ground wire in the event of the cable
being pulled.
- If this unit is permanently connected to a xed electrical cable, the cable should be equipped with
a fault leak protector.
- If this unit is connected to a wall outlet, the outlet should be permanently
Unit with one gas oven or one electric oven :
- Remove rear cover S, figures【1】,【2】.
- Use a standard flexible cable to connect to terminal block T (fig.【3】&【4】).
- Secure the cable by means of cable clamp U (fig.【3】).
It is hazardous to put the appliance into service without connecting it to suitable
ground.