WB PM -110 5 / 64
EN FR NL DE
below standards: IEC -Edition . -/EN
-:/A: (Medical electrical equipment
-- Part : General requirements for basic safety and
essential performance), IEC- :/EN -
-: /AC: (Medical electrical equipment
-- Part -: General requirements for basic safety and
essential performance - Collateral standard: Electro-
magnetic compatibility - Requirements and tests),
IEC--:+AMD:/EN  -:/
A:(Medical electrical equipment –Part -:
Particular requirements for the basic safety and
essential performance of automated non-invasive
sphygmomanometers)EN -:  + A: 
(Non-invasive sphygmomanometers - Part : General
requirements), EN -:  + A:  (Non-in-
vasive sphygmomanometers - Par t : Supplementar y
requirements for electro mechanical blood pressure
measuring systems);ISO- :(Non-Invasive
Sphygmomanometers - Part : Clinical Validation Of
Automated Measurement Type).
6. SPECIFICATIONS
1 Product name: WBPM-110
2 Model: LA090207
3 Classication: Internally powered,
Type BF applied part, IP22, No AP
or APG, Continuous operation
4 Machine size: Approx.83mm X 74mm
X26mm( 3 9/32’’x 2 29/32’’x 1 1/32’’)
5 Cu circumference: 14cm-
19.5cm (5 1/2’’-7 11/16’’)
6 Weight: Approx71g (2 1/2oz.)
(exclude batteries and cu)
7 Measuring method: Oscillometric method,
automatic ination and measurement
8 Memory volume: 2×60 times
with time and date stamp
9 Power source: batteries: 2×1.5V SIZE AAA
10 Measurement range:
a Cu pressure: 0-300mmHg
b Systolic: 60-260mmHg
c Diastolic: 40-199mmHg
d Pulse rate: 40-180 beats/minute
11 Accuracy:
a Pressure: ±3mmHg
b Pulse rate: ±5%
12 Environmental temperature for
operation: 10°C~40°C(50°F~104°F)
13 Environmental humidity for
operation: ≤85%RH
14 Environmental temperature for storage
and transport: -20°C~50°C(-4°F~122°F)
15 Environmental humidity for storage
and transport: ≤85%RH
16 Environmental pressure: 80kPa-105kPa
17 Battery life: Approx 200 times.
18 All components belonging to the pressure
measuring system, including accessories:
Pump,Valve, LCD, Cu, Sensor
s
Note: These specications are subject to
change without notice.
7. NOTICE
1 Read all of the information in the
operation guide and any other literature
in the box before operating the unit.
2 Stay still, calm and rest for 5 minutes
before blood pressure measurement.
3 The cu should be placed at the
same level as your heart.
4 During measurement, neither speak
nor move your body and arm.
5 Measuring on left wrist for
each measurement.
6 Please always relax at least 1 or 1.5 minutes
between measurements to allow the
blood circulation in your arm to recover.
Prolonged over-ination (cu pressure
exceed 300 mmHg or maintained above15
mmHg for longer than 3 minutes) of the
bladder may cause ecchymoma of your arm.
7 Consult your physician if you have
any doubt about below cases:
a The application of the cu over a
wound or inammation diseases;
b The application of the cu on any limb
where intravascular access or therapy, or
an arterio-venous (A-V) shunt, is present;
c The application of the cu on the
arm on the side of a mastectomy;
d Simultaneously used with other monitor-
ing medical equipments on the same limb;
e Need to check the blood
circulation of the user.
8
This Electronic Sphygmomanometer
is designed for adults and should never
be used on infants or young children.
Consult your physician or other health care
professionals before use on older children.
9 Do not use this unit in a moving vehicle; this
may result in erroneous measurement.
10 Blood pressure measurements determined
by this monitor are equivalent to those
obtained by a trained observer using the
cu/stethoscope auscultation method,
within the limits prescribed by the American
National Standard Institute, Electronic
or automated sphygmomanometers.
11 Information regarding potential electro-
magnetic or other interference between
the blood pressure monitor and other
devices together with advice regarding
avoidance of such interference please see
part ELECTROMAGNETIC COMPATIBILITY
INFORMATION.It is suggested that the blood
pressure monitor be kept 10 meters away
from other wireless devices, such as WLAN
unit, cell phone, microwave oven, etc.
12 If Irregular Heartbeat (IHB) brought by
common arrhythmias is detected in the
procedure of blood pressure measurement,
a signal of will be displayed.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lanaform LA090207 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info