703320
1
Zoom out
Zoom in
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111656/0218
TECHNICAL DETAILS
Hardware
Power supply Internal power supply unit (100–240 V, 50-60 Hz)
Power consumption Max. 23 W
Environment Temperature range 0–40 °C, humidity 0–95 %; non-condensing
Housing Robust metal housing, 1 HU with mounting brackets for 19“ installation, W 345 x H 44 x D 253 mm)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
VDSL 1 / VDSL 2 A VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a
A Compatible to VDSL2 from Deutsche Telekom AG
A VDSL2 vectoring as per ITU G.993.5
A ADSL conformity according to:
ADSL2+ over ISDN as per ITU G.992.5 Annex B /J with DPBO (over POTS: Annex A/Annex M),
ADSL2 over ISDN as per ITU G.992.3 Annex B (over POTS: Annex A/L),
ADSL over ISDN as per ITU G.992.1 Annex B (over POTS: Annex A)
A Supports just one virtual connection at a time in ATM (VPI-VCI pair) per modem
WAN 1 / WAN 2 WAN 1 SFP: Compatible with optional LANCOM SFP modules. Set as a WAN port ex-factory, can be
congured as a LAN port.
WAN 1 / WAN 2 TP: 10 / 100 / 1000 Base-TX, autosensing full duplex (WAN 1) / autosensing
(WAN 2), auto node hub
ETH1 - ETH 4 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in
the LCOS conguration.
Analog 1 - Analog 4 Use the cables of your analog devices to connect them with the analog interfaces. If necessary, use
the enclosed adapters.
ISDN 1 / ISDN 2 ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the
settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device.
ISDN 2: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to the ISDN
interface.
Cong (Com) / V.24 Serial conguration interface / COM-port: 9,600 - 115,200 baud
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server), serial devices (COM-port
server) or USB drives (FAT le system)
4G Two SMA connectors for the supplied dipole rod antennas (LTE, UMTS), compatible LANCOM
AirLancer antennas for 4G, or from other manufacturers. Please respect the restrictions which apply
in your country when setting up an antenna system (in particular the antenna gain and transmission
power).
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without DHCP),
RIP-1, RIP-2, VLAN, GRE, EoGRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and IPv4/IPv6 dual stack
session), IP(v6)oE (autoconguration, DHCPv6 or static)
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Data transmission in cellular networks
Supported standards UMTS, HSxPA, HSPA+, LTE, LTE Advanced
Supported cellular
network bands
Band 1 (2100 MHz), band 2 (1900 MHz), band 3 (1800 MHz), band 4 (2100 MHz),
band 5 (800 MHz), band 7 (2600 MHz), band 8 (900 MHz), band 12 (700 MHz),
band 13 (700 MHz), band 20 (800 MHz), band 25 (1900 MHz), band 26 (800 MHz),
band 29 (700 MHz), band 30 (2300 MHz), band 41 (2500 MHz)
Max. transmission power +23 dBm
Declaration of Conformity
Hereby, LANCOM Systems declares that this radio equipment is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address: www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN)
Cables for over ISDN: 2 DSL cables for an IP-based line, 4.25 m; 1 ISDN cable, 3 m (light-blue connectors);
for over POTS: 2 DSL cables, 3 m (dark-blue connectors);
1 Ethernet cable, 3 m (kiwi colored connectors); 1 IEC power cord 230 V (not for WW devices)
Antennas Two LTE / 4G antennas for LTE / UMTS
Adapters 4 TAE adapters (RJ11 - TAE)
Mounting brackets Two 19” brackets for rack mounting
MOUNTING AND CONNECTING THE DEVICE
a VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
f ISDN 1 (TE/NT) / ISDN 2 (NT)
Off Interface deactivated
Green, permanently D-channel active
Green, blinking ISDN connection active
Orange, blinking ISDN connecting
Green / orange, blinking
synchronously
ISDN hardware error
Orange, permanently Connection inactive
a POWER
Off Device switched off
Green, permanently* Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinking No password set. Without a password
the conguration data in the device is
unprotected.
Red, blinking Charge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code not
available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
c VDSL 1 / VDSL 2
Off Interface deactivated
Green, blinking DSL connecting
Green, pemanently DSL connection active
Green, ickering DSL data transmission
Green / orange, ickering DSL transmission error
Green / orange, blinking
synchronously
DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
a 4G
Off Cellular interface disabled
Green,permanently Connection to cellular network active
Green, ickering Cellular data transmission
Orange, permanently Logon to cellular network successful
Orange, blinking Logging on to cellular network
Red, permanently Hardware error / module unavailable
Red / green, blinking SIM card error (PIN)
Red / orange, blinking Uploading module rmware
a VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts (outgoing)
were successfully registered
Red, permanently Not all of the dened and active SIP accounts
were registered (possibly still in process)
Red or green,
inverse ashing
Number of currently used lines
(connecting or connected)
e ETH 1 - ETH 4
Green, orange off No networking device connected
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
d WAN 1 / WAN 2
Green, orange off No networking device connected
Green, permanently Connection to network device operational,
no data trafc
Green, ickering Data transmission
Orange off 1000 Mbps
Orange, permanently 10 / 100 Mbps
b RESET
Reset button short press > Restart the device
long press > Reset the device
*) The additional power LED statuses are displayed in 5-seconds rotation
if the device is congured to be managed by the LANCOM Management
Cloud.
This product contains separate open-source software components which
are subject to their own licenses, in particular the General Public License
(GPL). The license information for the device rmware (LCOS) is available
on the device‘s WEBcong interface under “Extras > License information“.
If the respective license demands, the source les for the corresponding
software components will be made available on a download server upon
request.
a c eb fd
4
Please observe the following when setting up the device
A The mains plug of the device must be freely accessible.
A For devices to be operated on the desktop, please attach the adhesive rubber
footpads
A Do not rest any objects on top of the device and do not stack multiple devices
A Keep the ventilation slots on the side of the device clear of obstruction
A Mount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
Pay attention to the “R” and “L” marks on the brackets for accurate mounting.
a
4G / LTE antenna connectors
Connect the supplied cellular antennas to the connectors
at the front of the device.
b
VDSL / ADSL interfaces*
If required, use the supplied DSL cables for the IP-based line to con-
nect each VDSL / ADSL interface to a separate provider’s telephone
socket. For more information, please contact your Internet service
provider.
*For operation with over POTS devices please use the enclosed DSL
cables with the dark blue plugs.
c
WAN 1 interfaces (SFP / TP combo port)
Insert a suitable SFP module (e.g. 1000Base-SX or 1000Base-LX)
into the SFP port. Choose a cable compatible with the SFP module
and connect it as described in the module’s documentation. SFP
modulel and cable are not included.
If desired, alternatively connect the WAN 1 TP interface to a WAN
modem using an ethernet cable.
d
WAN 2 interface (TP)
Connect the WAN 2 interface to a WAN modem using an Ethernet
cable.
e
Ethernet interface
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
f
Analog interfaces
Connect analog terminal devices to the analog interfaces either
directly via RJ11 or with the help of the enclosed TAE adapters.
g
ISDN interfaces
ISDN 1: Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2: Internal (NT) ISDN-bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
h
SIM card slots
Slide the SIM card(s) into slot SIM1 or SIM2 using the marker
to ensure that the card is the right way round. Ensure that the
SIM card clicks into place on insertion. To remove the card from
the device, press the card lightly into the device.
Let go to release the SIM card from the slot.
SIM
i
Conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
j
USB interface
You can use the USB interface to connect a USB printer or a
USB storage device.
k
l
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply.
Warning! High touch current.
Connect to earth before
connecting the power supply.
h
i
j
c
d
b
e
f
POWER
1 1
g
POWER
K
L
LANCOM 1906VA-4G
Quick Reference Guide
Cloud-ready

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lancom 1906VA-4G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Lancom 1906VA-4G

Lancom 1906VA-4G Installationsanweisung - Deutsch - 18 seiten

Lancom 1906VA-4G Kurzanleitung - Deutsch - 1 seiten

Lancom 1906VA-4G Installationsanweisung - Englisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info