703333
1
Zoom out
Zoom in
Power
When connecting the cable
to the device, turn the bayo-
net connector 90° clockwise
until it clicks into place.
Use only the supplied power
adapter.
VDSL
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. Subject to change without notice. No liability for
technical errors and/or omissions. 111530/0816
4
Please observe the fol-
lowing when setting up
the device
a For devices to be
operated on the
desktop, please attach
the adhesive rubber
footpads
a Do not rest any objects
on top of the device
a Keep the ventilation
slots on the side of
the device clear of
obstruction
a In case of wall
mounting, use the
drilling template as
supplied
a Rack installation with
the optional LANCOM
Rack Mount (not
supplied)
LANCOM 1681V
Power
VDSL
Online
ETH 1
ETH 2
VPN
ETH 3
ETH 4
ISDN Status
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 14 W
Environment Temperature range 0 – 40°C, humidity 0 – 95%,non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting,
Kensington lock; measures 210 x 45 x 140 mm (W x H x D)
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
LANCOM 730VA over ISDN
WAN: VDSL2
a VDSL2 as per ITU G.993.2; profiles 8a, 8b, 8c, 8d, 12a, 12b, 17a
a Compatible to VDSL2 from Deutsche Telekom
a Compliant to: ADSL2+ over ISDN as per ITU G.992.5 Annex B with DPBO, ADSL2 over
ISDN as per ITU G.992.3/5 Annex B/J, ADSL over ISDN as per ITU G.992.1 Annex B
a Supports just one virtual connection at a time in ATM (VPI-VCI pair)
ETH 4 individual ports, 10/100/1000 Mbps Gigabit Ethernet, by default set to switch mode. Up to 3
ports can be operated as additional WAN ports. Ethernet ports can be electrically disabled in
the LCOS configuration.
Config (Com) Serial configuration interface / COM port (8-pin Mini-DIN):
9,600 – 115,000 baud, suitable for optional connection of analog/GPRS modems. Supports
internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
DHCP), RIP-1, RIP-2, VLAN, GRE, L2TPv2 (LAC or LNS), IPv6 over PPP (IPv6 and IPv4/IPv6 dual
stack session), IP(v6)oE (autoconfiguration, DHCPv6 or static)
Declaration of conformity
For the declaration of conformity, see the product page on our website www.lancom-systems.eu
Package content
Manual Hardware Quick Reference (DE/EN),
Installation Guide (DE/EN)
Cable 1 DSL cable for an IP-based line, 4.25m
Power adapter External power supply adapter (230 V), NEST 12 V/1.5 A DC/S, barrel connector 2.1/5.5 mm
bayonet,
LANCOM Art.-No. 110723 or 111301 (EU,230V);
LANCOM Art.-No. 110829 or 111302 (UK, 230V)
LANCOM 730VA
DSL
ETH 2
Power
ETH 1
Online
ETH 4
ETH 3
a Power
Off Device switched off
Green on,
permanently
Device operational
Blinking
green/orange
Configuration password not set. Without a
configuration password, the configuration
data in the device is unprotected.
Blinking red Charge or time limit reached
b Online
Off WAN connection inactive
Green on,
permanently
WAN connection active
Red on,
permanently
WAN connection error
d ETH
Off No networking device attached
Green on,
permanently
Connection to network device operational,
no data traffic
Flickering green Data transmission
a b c d
S E T T I N G U P A N D C O N N E C T I N G T H E D E V I C E
T E C H N I C A L D A T A
LANCOM 730VA
Quick Reference Guide
This product contains separate modem firmware with open-source software components. These are subject to their
own licenses, in particular the General Public License (GPL). The license text for the modem firmware is available at
http://www.lancom-systems.de/docs/GPL/LC-DSL-Modem-Firmware-License-EN.txt. If the respective license demands,
the source files for the corresponding software components will be made available on a download server upon request.
Serial interface
Configuring the device via
the serial interface requires
a serial configuration cable
(available as an accessory).
Ethernet interface
Use the cable to connect one of
the interfaces ETH 1 to ETH 4 to
your PC or a LAN switch.
VDSL interface
Use the supplied DSL
cable for the IP-based
line to connect the VDSL
interface and the provider's
telephone socket. For
more information, please
contact your Internet service
provider.
ba
c
d
a cb d
c DSL
Off Interface deactivated
Green, on (constant) DSL connection active
Green, flickering DSL data transfer
Red, flickering DSL transfer error
Red/orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, on (perma-
nently)
DSL sync
Green, blinking DSL connecting

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lancom 730VA wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Lancom 730VA

Lancom 730VA Installationsanweisung - Deutsch - 18 seiten

Lancom 730VA Kurzanleitung - Deutsch - 1 seiten

Lancom 730VA Installationsanweisung - Englisch - 18 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info