Accessories2 Ethernet cables, 3 m (kiwi colored connectors); 1 serial conguration cable 1.5 m;
1 IEC power cord 230 V (not for WW devices); 1 grounding screw
MOUNTING AND CONNECTING THE DEVICE
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111749/0718
LANCOM ISG-4000
Quick Reference Guide
Cloud-ready
a
USB interface
You can use the USB interface to connect a USB printer or a USB
storage device.
b
Serial conguration interface
Use the included serial conguration cable to connect the serial
interface (COM) to the serial interface of the device you want to
use for conguring / monitoring.
c
SFP / TP Ethernet interfaces (combo ports)
Insert suitable SFP modules into the SFP ports ETH 1 - ETH 4.
Choose cables compatible with the SFP modules and connect them
as described in the module’s documentation. SFP modules and
cables are not included.
d
If desired, alternatively connect the ETH 1 - ETH 4 TP Ethernet inter-
faces to your PC or a LAN switch using one of the enclosed cables
with the kiwi-colored connectors.
e
TP Ethernet interface
Use one of the enclosed cables with the kiwi-colored connectors to
connect the interface ETH 5 to your PC or a LAN switch.
f
SFP+ interfaces (10G)
Insert suitable SFP modules into the SFP ports ETH 6 - ETH 7.
Choose cables compatible with the SFP modules and connect
them as described in the module’s documentation.
SFP modules and cables are not included.
g
Reset button
Pressed up to 5 seconds: device restart
Pressed until rst ashing up of all LEDs:
conguration reset and device restart
h
Power connector and grounding point (device back side)
Supply power to the device via the power connector. Please
use the IEC power cable supplied (separately available for WW
devices).
Warning! High touch current.
Connect to earth before
connecting the power supply.AC Line: 100-240 V 50-60 Hz
i
ATTENTION: High touch current possible! Connect to earth
before connecting the power supply. For this purpose, remove
the existing blind screw and use the enclosed grounding screw
instead.
4
Please observe the following when setting up the device
AThe mains plug of the device must be freely accessible.
AFor devices to be operated on the desktop, please attach the adhesive rubber
footpads.
ADo not rest any objects on top of the device and do not stack multiple devices.
A Keep the ventilation slots on the side of the device clear of obstruction.
AMount the device into a 19” unit in a server cabinet using the provided screws and mounting brackets.
H
I
LANCOM ISG-4000
RESET
COMUSB
TEMP
POWER
ETH 5ETH 6 (10G)ETH 7 (10G)
ETH 3
ETH 4
ETH 1
ETH 2
a
bcd
e
cdg
dETH 1 - ETH 4 - TP (one green and orange LED each)
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
bTEMP
Green, permanentlyCPU temperature OK
Red, blinkingHardware failure of the fan or CPU
temperature too high; additional acoustic
signal
eETH 1 - ETH 4 - SFP (one green and orange LED each)
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
aPOWER
OffDevice switched off
Green, permanently*Device operational, resp. device paired /
claimed and LANCOM Management Cloud
(LMC) accessible
Green / red, blinkingNo password set. Without a password
the conguration data in the device is
unprotected.
Red, blinkingCharge or time limit reached
1x green inverse
blinking*
Connection to the LMC active, pairing OK,
device not claimed
2x green inverse
blinking*
Pairing error, resp. LMC activation code
not available
3x green inverse
blinking*
LMC not accessible, resp. communication
error
cLCD display (rotating in two lines)
ADevice name
AFirmware version
ADevice temperature
ADate and time
ACPU load
AMemory usage
ANumber of VPN tunnels)
AData transfer in reception direction
AData transfer in transmission direction
fETH 5
Both LEDs offNo networking device attached
Green, permanentlyConnection to network device operational,
no data trafc
Green, ickeringData transmission
Orange off1000 Mbps
Orange, permanently10 / 100 Mbps
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
f
LANCOM ISG-4000
RESET
COMUSB
TEMP
POWER
ETH 5ETH 6 (10G)ETH 7 (10G)
ETH 3
ETH 4
ETH 1
ETH 2
a
bc
edd
ef
g
gETH 6 - ETH 7 - SFP+ (one blue LED each)
OffNo networking device attached
Blue, permanentlyConnection to network device operational,
no data trafc
Blue, ickeringData transmission
Brauchen Sie Hilfe? Stellen Sie Ihre Frage.
Missbrauch melden von Frage und/oder Antwort
Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.
Art des Missbrauchs:
Forenregeln
Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:
Lesen Sie zuerst die Anleitung;
Schauen Sie nach, ob die Frage bereits gestellt wurde;
Stellen Sie die Frage so deutlich wie nur einigermaßen möglich;
Erwähnen Sie was Sie bereits versucht haben um das Problem zu lösen;
Ist Ihr Problem von einem Besucher gelöst dann lassen Sie ihn / sie wissen in diesem Forum;
Falls Sie reagieren möchten, so verwenden Sie bitte das Antworten- Formular;
Da ihre Frage für alle Besucher sichtbar ist, sollten Sie lieber keine persönliche Daten erwähnen.
Neu registrieren
Registrieren auf E - Mails für Lancom ISG-4000 wenn:
neue Frage gestellt werden
neue Handbücher vorhanden sind
Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.
Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.
Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.
Ihre Frage wurde zu diesem Forum hinzugefügt
Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.