· Vent the unit before operation.
· Unscrew the high-pressure line at the high-pressure
outlet of the unit.
· Switch on the unit and let it run until water free of
bubbles emerges at the high-pressure outlet.
· Switch off the unit and screw on the high-pressure
hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
> ELECTRICITY SUPPLY
- The appliance’s electrical connection must
comply with the IEC 60364-1 standard.
IMPORTANT:
Before connecting the ap-
pliance, make sure that the nameplate data
are the same as those of the electrical mains
and that the socket is protected by a differ-
ential security breaker with tripping sensitiv-
ity below 0.03 A - 30 ms.
- If the appliance’s plug is not compatible
with the socket, have the socket replaced
with another of suitable type by profession-
ally qualified staff.
- Never use the appliance in ambient temper-
atures below 0° C if it is equipped with a PVC
(H VV-F) cable.
XY WARNING: Inadequate extension cords
can be dangerous.
XJ WARNING: If an extension cord is used,
the plug and socket must be of watertight
construction.
Information for supply may also be obtained
from the plug manufacturer.
<16 A <25 A
<20 m ø 1,5 mm
2
14 AWG
ø 2,5 mm
2
12 AWG
20 m - 50 m ø 2,5 mm
2
12 AWG
ø 4,0 mm
2
10 AWG
> PLUG
HOW TO CONNECT THE CORD TO A U.K. PLUG:
IMPORTANT The wires in the mains lead are col-
oured in accordance with the following code:
Blue Neutral
Brown Live
Yellow/Green Earth
Please read the instructions given below before con-
necting the cord to a plug. If in doubt please consult
a qualified electrician.
As the colours of the
wires in the mains
lead of this appliance
may not correspond
with the coloured
markings identifying
the terminals in your
plug, proceed as fol
-
lows: The wires that is
coloured Brown must
be connected to the
terminal which is
marked with the let
-
ter L or coloured Red. The wire that is coloured Blue
must be connected to the terminal wich is marked
with the letter N or coloured Black. Safety points for
rewireable or moulded plug: The mains lead of this
appliance may be already fitted with a BS1363 13A
plug.
- If your socket outlet is not suitable for the plug, then
the plug must be removed (cut off if it is a mould
-
ed on plug), the flexible cord insulation should be
stripped back as appropriate and a suitable 3 pin
plug fitted.
WARNING: Dispose of a plug that has been cut from
the power supply cord, as such a plug is hazardous
if inserted in a live 13A socket outlet elsewhere in
the house. - Should the fuse need to be replaced
an ASTA marked fuse, approved to BS1362, of the
same rating must be used. - Always replace the fuse
cover after fitting a fuse. The plug must NOT be used
if the cover is omitted or lost until a replacement is
obtained. - Make certain that only the correct fuse
cover is used and fitted. - For plugs with detachable
fuse cover the replacement must be the same as the
colour insert in the base of the plug, or as directed by
the embossed wording on the base of the plug. - If
the detachable fuse cover is lost a replacement may
be purchased from a Service Centre.
( if fitted)
NOTE:
(Automatic Stop System),
which stops the machine during the bypass phase.
To start the water cleaner, it is therefore necessary to
set the switch on position (I)“ON”; after that press the
pistol trigger: the Automatic Stop System will start
the machine and will stop it automatically when
the trigger is released. It is advisable to put on the
safety of the pistol trigger whenever the machine is
stopped, in order to avoid unintentional starting.
4 -
19

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lavorwash XTR 1007 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info