TECHNICAL DATA
Camera type Leica S (Typ 006) Digital medium format reflex camera
Lens connection Leica S bayonet
Lens system Leica S lenses
Picture format / Aspect ratio 30 x 45mm / 2:3
Image sensor / Resolution Low noise CCD sensor with 6µm pixel
pitch, with micro-lenses and micro-lens shift / 7500 x 5000 (37.5MP)
Dynamic range 12 stops
Color depth 16Bit
Low pass filter None, for maximum transmission of sharpness, sup-
pression of Moiré by external digital processing
IR filter On sensor
Data formats DNG (raw data, uncompressed or loss free compres-
sion), DNG + JPEG fine, DNG + JPEG basic, JPEG fine, JPEG basic.
DNG/JPEG resolution DNG: 37.5MP, JPEG: 37.5MP, 9.3MP, 2.3MP
File size DNG: Approx. 72/42 MB (uncompressed/compressed),
JPEG: Approx. 1-16 MB (depending on resolution/compression used
and picture content)
Buffer memory 2GB, maximum number of pictures in series (depend-
ing on memory card used): DNG uncompressed/compressed: maximum
28/32, JPEG:unlimited
Color space Adobe® RGB, sRGB, ECI RGB V2
White balance Automatic, manual, 8 presets, color temperature
metering
Storage medium CF cards (max. UDMA7), SD cards up to 2GB,
SDHC cards up to 32GB, SDXC cards
Menu languages German, English, French, Spanish, Italian, Japa-
nese, traditional Chinese, simplified Chinese, Russian
Compatibility Windows® XP / Vista® / 7®; Mac® OS X (10.5 and
higher)
Exposure control
Exposure metering Open aperture metering through the lens (TTL)
Metering methods Spot (3.5%), center weighted, multiple field
metering (5 fields)
Metering memory lock Pressing shutter release button to pressure
point, storing for 1 picture or continuously using joystick
Exposure compensation ±3 EV (exposure values), adjustable in half
steps
Bracketing Choice of 3 or 5 pictures, with choice of 1/2 EV, 1EV, 2EV,
3EV variation between individual pictures, change of exposure produced
by aperture and/or shutter speed depending on set exposure mode
Metering range (at f/2.5 and ISO 100) Spot metering: EV2,1 - 20,
center-weighted and multiple field metering: EV1,1 - 20, warning display
in viewfinder for values above/below metering range, measuring cell
for available light: multiple field photo diode (continuous light measure-
ment)
Sensitivities ISO100, ISO200, ISO400, ISO800, ISO1600, Automatic
Exposure modes Automatic program with shift function
(), aperture priority ( ), shutter speed priority ( ), manual setting ( )
Flash exposure control
Flash unit connections Accessory shoe with center and control
contacts, LEMO® or standard flash connecting socket without output
control
Synchronization Flash sync speed: 1/125 s, or 1/1000 s for lenses
with central shutter, slower shutter speeds available, choice of start or
end of exposure; flash with faster shutter speeds (1/180 s 1/4000 s) also
possible with flash units with corresponding features (HSS mode)
Flash measuring cell Multiple field photo diode
Flash exposure metering / control (with Leica SF 58 or system-com-
patible flash units, mounted on camera) Control by flash unit with TTL
pre-flash metering, with automatic transmission and consideration of
sensitivity and set/controlled lens aperture, all exposure modes avail-
able, automatic adaptation of flash light component to available light
High speed sync mode (with Leica SF 58 or system-compatible flash
units, with TTL pre-flash metering and automatic TTL HSS control) For
flash photography with faster shutter speeds than the sync time by emit-
ting several flashes in rapid succession, automatic switch to TTL HSS
mode (with TTL HSS mode on the flash unit) if sync speed is not reached
Strobe flash mode (multiple flashes fired during one exposure)
Automatic adjustment of exposure time in P and A exposure modes and
with system compatible flash units with appropriate features
Flash exposure compensation Can be set on flash units with appro-
priate features (Leica SF 58: ±3EV in 1/3 EV steps)
Displays in flash mode Ready status indicated by flashing or con-
stant illumination of flash symbol in viewfinder
Flash reflector illumination angle Automatic adaptation to the
focal length used with Leica SF 58 or system-compatible flash units with
motorized zoom reflector
75

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Leica S wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Leica S

Leica S Bedienungsanleitung - Deutsch - 72 seiten

Leica S Kurzanleitung - Englisch - 28 seiten

Leica S Bedienungsanleitung - Holländisch - 78 seiten

Leica S Bedienungsanleitung - Französisch - 72 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info