MAINTENANCE
17
MAINTENANCE
If the air conditioner will not be used for an extended of time, dry the air conditioner to maintain it
in best condition.
1 Dry the air conditioner in Fan mode for 3 to 4 hours and disconnect the power plug. There
may be internal damage if moisture is left in components.
2 Before using the air conditioner again, dry the inner components of the air conditioner in Fan
mode for 3 to 4 hours. This will help to remove odor which is generated from moisture.
Clean the product regularly to maintain optimal performance and to prevent possible breakdown.
* This may not be provided, depending on the model.
* The feature can be changed according to type of model.
Type Description Interval
Air filter See “Cleaning the filter.” 2 weeks
Ionizer See “Cleaning the Ionizer” 6 months
3M filter See ” Cleaning the 3M filter ” 1 months
Indoor unit
Clean the Indoor unit surface by using a soft, dry cloth. Regularly
Clean the condensate drain pipe. Every 4 months
Clean the condensate drain pan. Once a year
Thoroughly clean the heat exchanger. Once a year
Replace the remote control batteries. Once a year
Outdoor unit
Use steam to clean the heat exchanger coils and the
panel vents. (consult with technician)
Regularly
Clean the fan. Once a year
Clean the condensate drain pan. Once a year
Verify that all the fan assembly is firmly tightened. Once a year
Verify that electric components with jets of air. Once a year
Clean the electric components with jets of air. Once a year
ENGLISH