12
Interior light
Compressor
compartment
ventilation grille
Lock
Operating and
control elements
Defrost drain
Setting up
• Do not place the appliance in areas of direct sunlight or next to
a stove, heater or similar object.
• The floor on which the appliance stands must be horizontal and
level. Place the appliance far enough away from the wall so that
the lid can be opened and closed unhindered.
• Do not cover the gap between the lower edge
of the freezer and the floor, as the refrigeration
unit has to be supplied with air for cooling.
‚ There must be a gap of at least 20 cm between
the ventilation grille and
the wall. This gap must
be kept clear and the
ventilation openings un-
covered.
ƒ Do not place any objects
immediately next to the
outer housing of the
appliance. There must
be a gap of at least 20
mm all round in order to
ensure adequate heat
discharge.
• Standard EN 378 specifies that the more refrigerant there is in
the device, the larger the room in which the device is located
must be. In rooms that are too small a flammable gas-air mixture
can develop in the event of a leak The installation room must
use 8 g of refrigerant be at least 1 m3 in size. Information on the
refrigerant contained is on the name plate inside the device.
.
Important!
Before starting up the appliance, plug the defrost drain opening in
the floor of the appliance with the plug provided. This is important
to ensure that the appliance works properly.
Description of the appliance
Dimensions (mm)
Model A B C
CFf 1870 825 1045 702
CFf 2080 825 1255 702
CFf 2500 825 1675 702
CFd 2085 825 1255 709
CFd 2505 825 1675 709
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the type
plate.
The position of the type plate is shown in
the section entitled Description of the appliance.
Climate rating Room temperature
SN +10°C to +32°C
N +16°C to +32°C
ST +16°C to +38°C
T +16°C to +43°C
SN-ST +10°C to +38°C
SN-T +10°C to +43°C
Fault-free operation of the appliance is ensured provided that the
ambient temperature does not fall below -15°C.
Rear View
Type plate
EN