Chapter 5
Advanced Configuration
53
8-Port 10/100/1000 Gigabit Switch with Webview
all error reporting. For example, Syslog and local device
reporting messages are assigned a severity code, and
include a message mnemonic, which identifies the source
application generating the message. It allows messages
to be filtered based on their urgency or relevancy. Each
message severity determines the set of event logging
devices that are sent per each event logging.
Logging Indicates if device global logs for Cache, File,
and Server Logs are enabled. Console logs are enabled by
default.
Emergency The system is not functioning.
Alert The system needs immediate attention.
Critical The system is in a critical state.
Error A system error has occurred.
Warning A system warning has occurred.
Notice The system is functioning properly, but system
notice has occurred.
Informational Provides device information.
Debug Provides detailed information about the
log. If a Debug error occurs, contact Customer Tech
Support.
Admin > Port Mirroring
Admin > Port Mirroring
Port mirroring monitors and mirrors network traffic by
forwarding copies of incoming and outgoing packets
from one port to a monitoring port. Port mirroring can be
used as diagnostic tool and/or a debugging feature. Port
mirroring also enables switch performance monitoring.
Network administrators configure port mirroring by
selecting a specific port to copy all packets, and different
ports from which the packets are copied.
Source Port Defines the port to which traffic is mirrored.
Type Indicates the port mode configuration for port
mirroring. The possible field values are:
RxOnly Defines the port mirroring on receiving ports.
This is the default value.
TxOnly Defines the port mirroring on transmitting
ports.
Both Defines the port mirroring on both receiving and
transmitting ports.
Target Port Defines the port from which traffic is
mirrored.
Admin > Cable Test
The Cable Test screen shows you results from performance
tests on copper cables. The maximum cable length that
can be tested is 120 meters. Cables are tested when the
ports are in the down state, except for the Approximate
Cable Length test.
Admin > Cable Test
Port This is the port to which the cable is connected.
Test Result This is the test result. OK indicates that the
cable passed the test. No Cable means there is no cable
connected to the port. Open Cable means the cable is
connected on only one side. Short Cable indicates that a
short has occurred in the cable. Undefined indicates that
the test could not be properly performed.
Cable Fault Distance This is the distance from the port at
which the cable error occurred.
Last Update This is the last time the port was tested.
Test Click the Test button to perform the test.
59

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Linksys SRW2008 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info