22
Boat Setup Reset
If you want to access the Setup screen (Boat Setup) after an engine-
tank configuration has been chosen you will have to reset the
configuration to default settings.
To reset engine-tank configuration:
1. Press MENU, highlight SYSTEM SETUP and press ENTER.
2. Choose
ENG/TANK CFG and press ENTER twice. The following message
will appear: Press ENTER to reset Eng/Tnk Cfg.
3. Press
MENU. The Setup Menu will appear with Boat Setup
highlighted.
Fuel Remaining Source
The Fuel Remaining source function allows you to select the device
used to measure the amount of fuel remaining in the tank. It must be
set to Fuel Flow (Eng /FFlow) to work properly with the EP-60R. The
Fuel Remaining Source will be set to fluid level by default.
To change Fuel Remaining Source to fuel flow:
1. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
ENTER.
2. Highlight
FUEL SETUP and press ENTER.
3. Select
FUEL REM SRC (Fuel Remaining Source) and press ENTER.
4. Highlight
ENG/FFLOW (Fuel Flow) and press ENTER. You are ready to
configure your fuel flow sensor.
EP-60R Fuel Flow Configuration
You can have up to three fuel flow sensors installed on your vessel, one
for each engine supported by the LMF-400. When accessing a fuel flow,
its menu will appear with the following options: Change Engine (for
two or more engines only), Fuel Warning, Unset Engine, Reset Values
and Reset Calibration.
NOTE:
If, after configuring, unconfiguring or reconfiguring a fuel flow, it is
not shown on the Bus Devices list, you will have to refresh the list.
To do this, press
MENU, select SYSTEM SETUP and press ENTER.
Highlight
BUS DEVICES and press ENTER.
To configure a fuel flow:
When you configure a fuel flow, you are linking the fuel flow's
location/engine on the boat to its matching configuration name in the
LMF-400.