599356
12
Zoom out
Zoom in
Vorherige Seite
1/24
Nächste Seite
Automatic
Sensitivity
17
=
KEEL OFFSET'
When the X-50 is in the automatic
mode,
the
sensitivity
of the
receiver
will
be
adjusted
above the minimum
required
to
pick up
the bottom
signal.
This enables the X-50 to
display
fish, structure,
and other small
targets
while in the automatic mode.
The
sensitivity
level can
be
changed
while the X-50 is in the automatic
mode. This
may
be
desirable if the level of
sensitivity
chosen
by
the X-50 is
not
enough
to show fish
or other small detail. If
desired,
any
amount of
sensitivity up
to the
maximum
may
be added or
any
amount of
sensitivity
down to the minimum
may
be subtracted from the current
setting.
To
adjust
the
sensitivity
while the X-50 is in
the automatic
mode,
simply press
either the
right
arrow
key>
to increase the
sensitivity
or the
left arrow
key
C to decrease it.
Holding
the
keys
down will
increase or
decrease the
sensitivity
faster. If
the value
goes
below the
minimum,
the
X-50's audible tone will "flutter". The same is true if
you try
to
go
above the
maximum level. As
you press
the arrow
key,
the
sensitivity
bar will
move
right
or
left,
according
to the amount of
sensitivity
chosen. The X-50 will
still
automatically adjust
the
sensitivity
as conditions
change,
but it will
always keep
the
amount
that
you
added or subtracted.
Most sailboats have a keel or a centerboard that
extends
many
feet
below the surface.
Many power
boats with
displacement
hulls also extend
many
feet below the surface of the water. The
digital
sonar
calculates the
bottom
depth
from the transducer's face. If the boat hull sticks below the
transducer,
then it can run
aground
when the
digital says
there is still
clearance. The X-50
provides
a keel offset
adjustment
that allows for the
depth
correction between the face
of the transducer and the bottom of the
hull. For
example,
if the bottom of the hull is
4
feet
deeper
than the trans-
ducer
location,
then the keel offset
on the X-50 can be
adjusted by press-
ing
17 from the menu selection. A new menu
will
appear:
KEEL
OFFSET IS
0.0 FT
ENTER
VALUE
IN TENTHS
THEN PRESS
Sensitivity—Manual
Operation
At
times,
it
may
be desirable to turn the
automatic functions off and
"fine tune" the X-50 to
the current conditions.
To
manually adjust
the
sensitivity, press
the
AUTO
key
once,
and auto
sensitivity
will be turned
off. The word AUTO at the
top
of
the
display
will
disappear, signifying
that the X-50 is in the
manual mode. The
sensitivity
can now be
adjusted
to
the desired level.
Figure
6 demonstrates a
graph
with too little
sensitivity,
while on the
right,
the
sensitivity
is
adjusted
properly;
a fish is now
visible,
the surface
clutter is more
pronounced,
and the bottom
signal
has widened.
When the horizontal bar reaches the far
right
hand side of the
screen,
the
sensitivity
level is at maximum. If
high
sensitivity settings
are
used,
a
second bottom echo
may appear.
This is normal and is caused
by
the
returning
signal reflecting
off the surface of the
water,
making
a second
trip
to the
bottom and back
again.
This is
called "second echo".
Occasionally,
when
high sensitivity
levels
are
used,
the
display
will
turn black.
This
happens
when there are
large
amounts of
surface
clutter,
thermoclines,
turbulent
water,
or
suspended particles
such as silt that
reflect the sonar
signal.
This does not
damage
the
unit
to
correct
it,
simply
turn down the
sensitMty
level.
To
return
to
the Automatic
mode,
press
the AUTO
key. Remember,
both automatic
sensitMty
control and auto
ranging
functions are
turned off
and on
by pressing
the AUTO
key.
UPPER
LIMIT FOR
NEGATIVE
OFFSET
LOWER
LIMIT FOR
POSITIVE
OFFSET
Since the hull in our
example
boat is 4 feet
lower than the
transducer,
we want to use a
negative
offset.
So,
while
the above menu is still on the
screen,
press
40. This is
actually
4.0 feet.
(If you just press 4,
the offset will
be .4 or four tenths of a
foot.)
The X-50 will now
display
the
depth
with a
four foot offset In other
words,
if the bottom is
fifty
feet from
the transducer
face,
with a four foot
negative
offset the X-50 will
display
the bottom
depth
as 46 feet
10
35
OR
PDF compression, OCR, web-optimization with CVISION's PdfCompressor
12

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Lowrance X-50 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info