8 ENGLISH
4. Open the inlet valve.
5. Turn the pump on. If the pressure of the manifold
indicates a vacuum of -0.09 to -0.1 MPa within
30 seconds, the pump is operating properly.
6. Turn the pump off.
Operation
Fig.7:
1. Vacuum pump
2. Intake shut-off valve
3. Charging hose
(yellow)
4. Manifold
5. Low side valve
6. Low pressure gauge
7. High side valve
8. Charging hose (blue)
9. Service port
(Low pressure side)
10. Outdoor unit
1. Connect the pump, manifold and outdoor unit with
hoses.
NOTE: When the size of the service port on the unit is
1/4", use the supplied different diameter adapter.
2. Check that the high side and low side valves of the
manifold are closed.
3. Install the battery to the pump. (See “Installing
or removing battery cartridge” for the installation
method.)
4. Turn the pump on. The LED lamp (green) lights up.
5. Open the intake shut-off valve of the pump and the
low side valve of the manifold.
WARNING: The pump becomes hot during
operation and immediately after stopping. Do not
touch the pump while it is hot. Doing so may result in
burns or other accidents.
NOTE: The motor may not operate when it is cold (5°C
or less). In these cases, bring the pump indoors and
allow it to warm up.
6. When the specied vacuum (refer to the manual
provided by the air conditioner manufacturer) is
reached, close the low side valve of the manifold.
7. Close the intake shut-off valve and turn the pump
off.
Airtightness test
There are no leaks if the pressure of the manifold does
not rise for 5 minutes or more after leaving the pump and
manifold.
NOTE: When the battery remaining capacity becomes
low, LED lamp goes out and at the same time a long
alarm beep start sounding. About two minutes later
the motor stops. And then alarm beep changes into a
repeated short-time interval beeping which noties the
motor stop and 30 seconds later the beeping stops.
However, do not wait until the motor stops (or alarm
beep changes to a short-time beeping), and instead
close the inlet valve of the pump and the low pressure
side valve of manifold.
Check that the pump is turned off, remove the battery,
and charge it or replace it with a spare battery.
Refer to the following table for the battery operation
times.
Operation times (guideline)
Battery Operation times
BL1860B 75 min
BL1850 / BL1850B 50 min
BL1840 / BL1840B 40 min
BL1830 / BL1830B 30 min
After nishing work, remove the battery and attach
the supplied cover.
NOTICE: When transporting, operating and
storing the pump, never place it on its side or
upside down. This may cause oil leakage from the
oil ller/vent cap.
Transport and storage
Always drain your vacuum pump of all uids before
shipping to prevent the damage of the container.
Always cover the intake port with cap to keep any
dust from entering the pump.
Be sure that the pump is kept in a horizontal position.
The pump is stored in indoor ambient temperature
5°C – 40°C .
MAINTENANCE
CAUTION: Always be sure that the pump is
switched off and the battery cartridge is removed
before attempting to perform inspection or
maintenance.
NOTICE: Never use gasoline, benzine, thinner,
alcohol or the like. Discoloration, deformation or
cracks may result.
To maintain product SAFETY and RELIABILITY,
repairs, any other maintenance or adjustment should
be performed by Makita Authorized or Factory Service
Centers, always using Makita replacement parts.
Stop the pump:
To make pump life longer and smooth start-up, these
procedures to shut off pump should be followed.
1. Close the manifold valve between the pump and the
system.
2. Remove the hose from the pump inlet.
Cover the inlet port opening to prevent any contamination
or foreign particles from entering the port.
Checking the oil
Fig.8:
1. Level line 2. Sight glass
Always check the oil level and condition
(deterioration, etc.) before using the pump.
NOTE: Add oil until the oil level is between the upper
and lower level lines of the sight glass.
8

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Makita DVP180 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info