Manual for installation and operation, Comfort 211 accu, solar GB (#76810) 41
9. Extended operator functions
Caution!
To exclude any risk of injury, Menus 3 and 4 (automatic cut-out) may only be switched off if a photocell
barrier or closing edge safety device is installed.
*The higher the setting, the higher the driving power.
Level 2 – Operator settings
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 1: Required driving power to OPEN (sensitivity on a scale from 1 to 16*)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 2: Required driving power to CLOSE (sensitivity on a scale from 1 to 16*)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 3: Automatic cut-out OPEN (sensitivity on a scale from 1 to 16*)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 4: Automatic cut-out CLOSE (sensitivity on a scale from 1 to 16*)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 5: Speed OPEN (setting)
– – – – – – 7 8 9 10 11 12 13 14 15 16
Menu 6: Speed CLOSE (setting)
– – – – – – 7 8 9 10 11 12 13 14 15 16
Reference:
If changes are made in Menus 5 and 6 of Level 2, another learning run must be carried out to
determine the maximum driving power. The learning run procedure is described in Section 8.6.1.