Manual for installation and operation, Comfort 211 GB (#72752) 35
Error Cause Solution
LED 6 flashes
regularly.
A fault has occurred.
Give the P button a short press and one or more LEDs will flash irregularly. The fault number can be
found by adding together the numbers next to the flashing LEDs.
Message 6 - External photocell interrupted. - Remove obstacle.
Message 7 - If no buttons are pressed within 120 seconds, the programming mode terminates automatically.
- OPEN and CLOSED door positions programmed without passing the reference point.
Message 8 - Defective reference point switch. - Have the operator system checked.
Message 9 - Defective RPM sensor /
operator system blocked.
- Have the operator system checked.
Message 10 - Door movement too stiff.
- Door blocked.
- Ensure that the door moves easily.
- Maximum driving power setting is too
low.
- Have the max. driving power (Section 9.4 / Level 2 /
Menu 1+2) checked by an expert.
Message 11 - Excess travel stop. - Have the operator system checked.
Message 15 - External photocell interrupted or
defective.
- Remove obstacle or have the photocell checked.
- Programmed for photocell, but no
photocell is connected.
- Deactivate or connect the photocell.
Message 16 - Power sensor for the automatic
cut-out is defective.
- Have the motor unit checked.
10.3.2 Malfunctions with error messages