English Page 16
D. Installation
Separate door from operator
• Pull the cable (A) downward to the stop in order to separate the door
from the operator (Fig. D.22).
Connect door and operator again
• Push the red release pin (B) back in the direction of the arrow (D.24).
• Start the door operator.
The symbols on the downward side of the carriage show the actual situation:
The door is separated from the operator.
->The front edge of the movable slide element (C) is above the arrow
of the symbol 'lock open' (fig. D.23).
The door is connected to the operator or will be connected automatically
after the next door travel.
->The front edge of the movable slide element (C) is above the arrow
of the symbol 'lock closed' (fig. D.24).
Operational check:
After the operator has been mounted, the following tests have to
be carried out:
- In 'close' direction the door runs against an obstacle of 50 mm
that lies on the floor:
-> The door has to reverse.
For operators for doors with openings in the door wing
(diameter of the opening > 50 mm):
- A load of 20 kg is put to the middle of the bottom door edge:
-> The door stops as soon as the open command is given.