G. Display functions and programming possibilities
Advice:
Changes in the programming levels of the extended
operator functions may only be carried out by specialists!
Explanation of the extended operator functions:
Explanation
Setting whether the operator is
run with or without photocell.
The sensitivity of power limit
can be set in steps from 1 - 16.
The sensitivity of power limit
can be set in steps from 1 - 16.
The sensitivity of power limit
can be set in steps from 2 - 16.
The speed the door is moved
by the operator can be set
Functions
Menu 1:
- programming external
photocell
Menu 2:
- power limit OPEN
Menu 3:
- power limit CLOSE
Menu 4:
- offset learned power
limit
Menu 5:
- operator speed
Settings from factory
no photocell existing
step 5
step 5
step 13
step 16 (max. speed)
GB
English Page 59
G. Display functions and programming possibilities
Settings from factory
not possible
8 9 10 11 12 13 14 15 16
120 140 160 180 190 200 210 220 240
sec. sec. sec. sec. sec. sec. sec. sec. sec.
BUTTON