M07E027
6. Installation
Advice:
If a closing prevention device
(photocell, timer, …) is connected to
XB99, the controls will recognise it
automatically after “Mains On”
(contact SB34 must be closed).
The photocell can be deactivated later
(Level 8 / Menu 1).
When the contacts of a closing
prevention device are open, the gate
can no longer be closed.
Additional external control elements,
and safety and signal devices with 24 V
connections must be connected to
XB99 and XH01.
Connection option 3:
- External radio receiver
6.7 / 5
Label Type / function
XB99 Connection of external control elements
3 Connection for intermediate position
5 Stop connection
8 Impulse connection
34 Connection for closing prevention device
B9 24 V DC connection
X1 Connection for external receiver
1
Connection of potential-free normally open
contact
2
Connection of potential-free normally open
contact
+ 24 V DC connection
- GND connection
S1
Normally open contact, receiver,
potential-free
XH01 Connection of control unit output
15 Connection for electric lock, 24 V DC
16 GND connection
17 Connection for programmable output