Attention!
If a photocell is connected, it is automatically recognised by the controls after MAINS ON.
The photocell can be reprogrammed later.
Advice:
Photocells and closing edge safety devices that are not required must be disconnected, or the controls
will recognise them. Disconnected closing edge safety devices must be replaced with an 8.2 kΩ resistance.
If an external photocell is connected at terminals B9 and 34, the power supply must be switched off
and on again before programming the automatic closing timer.
9. Extended operator functions
Level 8 – System settings
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 1: Photocell (MASTER ONLY)
A1 B1 C1 D1 E1 F1 G1 H1 I1 J1 K1 – – – – –
Menu 2: Closing edge safety device (MASTER + SLAVE)
A2 B2 C2 D2 – – – – – – – – – – – –
Menu 4: Operating modes (MASTER ONLY)
A4 B4 C4 D4 – – – – – – – – – – – –
Menu 5: Function of the direction command transmitters (MASTER ONLY)
A5 B5 – – – – – – – – – – – – – –
Menu 6: Function of the impulse command transmitters (MASTER ONLY)
A6 B6 – – – – – – – – – – – – – –
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Operating Instructions, Comfort 580 GB (#91636) 45