17
5. Overview of connecting unit
A Mains connection 220 V - 240 V / 380 V - 415 V
B Motor connection 220 V - 240 V / 380 V - 415 V
C Limit switch connection 24 V DC
D Electronic aerial (if installed)
E Connection of coiled cable for optosensor, cable slack device and wicket door contact
F 5-pole coiled cable
G Connection of wicket door contact (if installed)
H Distributor housing connecting cable
I Distributor housing
6. Control 110
a. Control 110 wiring diagram with Dynamic 111,112 and 115 operator
F1 Fuse 80 mA
F2-F4 Main fuses 6.3 A
H1 „Control voltage“ LED
H2 „End of travel OPEN“ LED
H3 „End of travel CLOSE“ LED
H4 „Self-monitoring, remote control“ LED
K11,K21 Inversion relay „OPEN, CLOSE“
KL Photocell *
M1 Motor with thermal protection
R10 PTC short-circuit protection
S Main switch
SO „STOP“ button *
S0a Control 110, STOP button
Control 112, STOP button
Control 111, STOP switch, lockable
Control 113, STOP switch, lockable
SOH „STOP“ button
S1,S1a „Operate or pull switch“ button *
S2,S2a „OPEN“ buttons *
S2A „OPEN“ button
S4,S4a „CLOSE“ buttons *
S4Z „CLOSE“ button
S6a,S6b Limit switches, cable slack device or spring safety device *
S7 OPEN self-hold ON/OFF
S8a CLOSE self-hold ON/OFF
S8b CLOSE self-hold ON/OFF
S10 „Emergency hand chain“ limit switch
S11 „OPEN“ limit switch
S13 „CLOSE“ limit switch
S14 Limit switch „50 mm short reverse OFF“
S19 Programming switch, Control 200 / Control 300
S20 Photocell programming switch
S22 Power limit OPEN rotary switch
S23 Power limit CLOSE rotary switch
S24 Remote control coding button
T1 Transformer
V4 RPM detector
V5 Transmitter optosensor
V6 Receiver optosensor
X1 Power cable 3 - 220 V - 240 V / 380 V - 415 V; 50 Hz
X1a Power cable 3 - 220 V - 240 V; 50 Hz
X2 Plug-in connecting terminal for mains cable and operator
X2a Plug-in connecting terminal, limit switches and RPM detector
X2b Plug socket, optosensor circuit board
X2c Plug-in connecting terminal „command units (buttons)“
X2d Plug-in connecting terminal „command units (buttons)“
X2e Plug-in connecting terminal for photocell (Special)
X2f Plug connection Control 200 and Control 300
X3 Plug-in connecting terminal „operator“
X4 Plug socket for electronic aerial
X5 Plug connection „keyboard circuit board“
X7a Plug socket for optosensor circuit board
X7b Plug-in connecting terminal for coiled cable
X7c Plug-in connecting terminal for optosensor coiled cable
X7d Plug socket for cable slack device (with Dynamic 201 bridged)
X7e Plug socket for receiver optosensor