13
4.1 Closing edge safety device (CLOSE - bottom of door)
Function: This closing edge safety device monitors the bottom door seal. If whilst
closing the door meets with an obstruction, the closing edge safety
device automatically halts the door and lifts it to clear the obstruction.
Connecting the closing edge safety device
Insert the optosensor bungs into the bottom door seal and connect them to the
electricity supply.
4. Connecting the closing edge safety devices
* If connected, the short-circuit bridge must be removed.
+ Dynamic 121-128 only
Legend:
Programming switches:
S2b Press-and-release
operation mode
Switches (system plugs):
S5 Wicket door switch
S6 + Cable slack switch
Switches (screw terminals):
S5a * Wicket door switch
S6a * + Cable slack switch
S6b * Cable safety device
Plug connections:
X30 Closing edge safety device
X7a Coiled cable
X7d + Cable slack switch
X7e Optosensor receiver
X7f Connection lead
X7g Wicket door contact
Connecting terminals:
X2c Static current circuit (in
the control unit)
X7b Coiled cable
X7c Coiled cable
X7h Static current circuit
X7l Cable slack switch
Optosensors:
V5 Transmitter
V6 Receiver