English / Page 15
6. Display functions and programming possibilities
Explanation of the extended operator functions:
Programming level
8. level
Operating modes.
Table:
see page 19.
3. level
Automatic timer.
Table:
see page 20/21.
5. level
Operator lighting /
signal lights.
Table:
see page 22/23
6. level
Reversion modes
Table:
see page 24
Functions
- Press and hold OPEN.
- Press and hold CLOSE.
- Impulse commands.
- Direction commands
(push button OPEN or
CLOSE).
- Impulse function OPEN.
- Toraufzeit
- Warning time
- Warning before start
- Premature closing after
passing photocell
- Lighting time
- Signal lights
- Lighting
- Photocell OPEN
- Photocell CLOSE
- Closing edge safety device
OPEN
- Closing edge safety device
CLOSE
- Power limit OPEN
- Power limit CLOSE
Explanation
The operator travels after start to travel limit
OPEN.
The operator travels after start to travel limit
CLOSE.
A running operator may be stopped or not
by command.
A running operator may be stopped or not
by command.
Reversion or priority OPEN.
Time, in which the door is open, before
door closes automatically.
Time period, in which signal light flashes,
before door closes automatically.
Time period, in which signal light flashes,
before door starts to move.
The door closes either after set open time or
premature after passing photocell.
(Connection of lighting is not possible).
The signal lights flash or glow at power
operated movement of the door
(Connection of lighting is not possible).
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.
Adjustable for STOP, short or long reversion.