9. Extended operator functions
Level 5 – Special function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 1: Programmable impulse input - XB99 (MASTER ONLY)
A1 B1 – – – – – – – – – – – – – –
Menu 2: Start-delay for second motor unit (in seconds) (MASTER ONLY)
A2 B2 C2 D2 E2 F2 G2 H2 I2 J2 K2 L2 M2 N2 O2 P2
Menu 4: Lighting duration (in seconds) – Terminal 16/17
2 5 10 15 20 25 30 35 40 50 80 100 120 150 180 255
Level 4 – Remote programming
Menu 2: Active wing – remote impulse to operate one gate wing only (MASTER ONLY)
LED 7 flashes slowly -> press hand transmitter button -> LED 7 flashes quickly
A1 Connection option 1:
Terminal B9/3: Active wing
Terminal B9/8: Impulse (OPEN/STOP/CLOSE)
B1 Connection option 2:
Terminal B9/3: Direction command transmitter, CLOSE
Terminal B9/8: Direction command transmitter, OPEN
Menu 1: Programmable impulse input
Reference:
The programming of the special function is dependent on terminal XB99.
Terminal XB99 is described in Section 6.7.
The lighting duration programmed is only active when the relay output (Level 1 / Menu 7) is
programmed lighting (H7).