588460
25
Zoom out
Zoom in
Vorherige Seite
1/64
Nächste Seite
INSTALATION OF THE EXHAUST PIPE
The unit is a portable air conditioner that may be moved from
room to room.
1. Using the PVC strip (fig. 8)
2. Offer PVC strips to the window gap and adjust to size if
necessary.
Connect one end of the exhaust pipe to outlet of
exhaust air and the other end with the outward
adapter.
Feed the exhaust hose to the PVC strip as shown
and slide window across so that PVC strip is held
securely. Note: Take care to maintain protection
against intruders
3. Using the adaptor (fig. 9, 10)
Cut a 151mm diameter hole in the wall or window.
Feed exhaust hose through the window or wall and
attach the threaded adaptor from the outside as
shown.
When not in use, plug the hole with the cover
provided.
MOUNTING OF THE EXHAUST PIPE (Fig. 11 13)
Use only the hose provided and clip exhaust hose and unit
adaptor to the back of the air conditioner
Avoid kinks and bends in the exhaust hose as this will
cause expelled moist air to build up causing the unit to
overheat and shut down. Fig 8 & 9 show correct position
The hose may be extended from 300mm to 1500mm but
for maximum efficiency use the shortest length possible.
WARNING! (fig. 14)
The length of the exhaust pipe is specially
designed according to the specification
of this product. Do not replace or prolong
it with your own private hose as this could
cause the unit to mal-function.
Instalation of the carbon filter (fig. 15 20)
1. Draw out the filter frame from the unit. (Fig 15)
2. Remove the filter fixer from the filter frame. (Fig. 16)
3. Remove the active carbon filter from its plastic bag. (Fig.
17)
4. Attach the active carbon filter to the filter frame. (Fig. 18)
5. Attach the filter fixer to the filter frame (the active carbon
filter should be hold between the filter frame and filter
fixer firmly). (Fig. 19)
6. Insert the filter set (filter frame + active carbon filter +
filter fixer ) into the back of the unit. (Fig. 20)
CONTROL PANEL
Buttons (Fig. 21)
1. Receiver for remote control
2. ON/OFF button
3. Temperature increase button
4. Temperature decrease button
5. TIO2/ION button (this is option function, only for the
model with this function)
6. MODE selection button
7. SLEEP button
8. TIMER button
9. VENTILATION (fan speed) button
Sign in the LCD (Fig. 22)
10. Sign for Timer (showing the working hour you set)
11. Room temperature display
12. Sign for Sleep function
13. Sign for Centigrade or Fahrenheit (please refer to the unit
you have)
14. Sign for Heating function
15. Sign for Ventilation mode
16. Sign for Dry mode
17. Sign for Cooling mode
18. Sign for Automatic mode
19. Sign for Ventilation speed (1 to 3 speeds)
20. Sign for TiO2
21. Sign for Ionizer function
OPERATION.
Turning ON/OFF
Adjust the louvers to desired angle and position.
Press ON/OFF button, the unit will start to work. If the ambient
temperature is
higher than 23oC, the unit will work in cool mode.
higher than 20oC but below or equal to 23oC, the
unit will work in ventilation model.
below 20oC, the unit will work in heat function
(This is for cooling & heating models only.),
Indicators of the functions in progress come on at the same time.
*NOTE! The display window shows the ambient room
temperature from 0oC to 50oC
To turn the unit off, press ON/OFF button again, then close the air
louvers.
Setting mode/function
Press MODE button to select required working mode: automatic,
cooling, fan or heat (Heat is only available for heating & cooling
models.)
Indicator of the selected mode comes on.
Setting temperature
1. Press 'Temperature up' or 'Temperature down' button to
regulate the temperature you desired.
2. The display window will show the temperature you set as
you press 'Temperature up' or 'Temperature down' button.
Otherwise, it will always show the ambient temperature.
3. The pre-setting temperature of this machine is: 24oC for
cooling, 20oC for heating.
Setting ventilation speed
1. Press SPEED button to choose the ventilation speed you
need, high, medium or low. The sign of high, low or
medium ventilation will light on at the same time.
2. If the unit is in AUTO mode, it will choose the ventilation
speed automatically according to the ambient temperature.
Setting timer
1. Press TIMER button to set the operating hours you desired
(1 to 24 hours, the sign of timer will light on). The window
will show the hour(s) you set as you press TIMER button.
If the timer button is not pressed, the unit will work
continuously.
2. By pressing the timer but without turning on the other
functions, you can PRE-SET the time for the machine to
work. For example, if you press the timer to '2', the unit
will work automatically after 2 hours.
Sleep function
1. In cooling mode, by pressing the SLEEP button, the set
temperature will increase 1oC at the 1st hour, another 1 oC
at the second hour, then keeps at that temperature.
2. In heat mode, by pressing the SLEEP button, the set
temperature will descend 1oC at the 1st hour, another 1 oC
at the second hour, then keeps at that temperature.
3. In sleep mode, the ventilation will keep at low speed. Re-
press the SLEEP button, the setting temperature and
ventilation speed will return to the pre-selected one.
25

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

master-ac-1600-e

Suche zurücksetzen

  • Mein Klimagerät zieht die warme Luft nicht mehr ab, es ist immer gleich heiss. Ist etwas defekt oder mache ich
    etwas falsch. Eingereicht am 18-6-2021 10:59

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für master AC 1600 E wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info