A IR P U R GI N G AN D T E ST O P E RA T I ON
4
5
Liquid side:φ 6.35mm
R22: (Pipe length-5)x30g/m
R410A: (Pipe length-5)x20g/m
Liquid side:φ 9.52mm:
R22: (Pipe length-5)x60g/m
R410A: (Pipe length-5)x40g/m
Connective pipe length
Less than 5m
More than 5m
Air purging method
Use vacuum pump
Additional amount of refrigerant to be charged
Op en t he v al ve s te m un ti l it h it s ag ai ns t
th e st op pe r. Do no t tr y to o pe n it f ur th er.
Se cu re ly t ig ht en t he v al ve s te m ca p wi th
a sp an ne r or t he l ik e.
V al ve s te m ca p ti gh te ni ng t or qu e. S ee
Tig ht en in g to rq ue t ab le .
.
.
.
.
Flare nut
Stopper
Cap
V alve body
V alve stem
Use vacuum pump
Fo r th e R4 07 C re fr ig er an t mo de l, m ak e su re t he r ef ri ge ra nt a dd ed i nt o ai r co nd it io ne r is l iq ui d
fo rm i n an y ca se s.
Wh en r el oc at e th e un it t o an ot he r pl ac e, u si ng v ac uu m pu mp t o pe rf or m ev ac ua ti on .
.
.
.
.
Ai r an d mo is tu re i n th e re fr ig er an t sy st em h av e un de si ra bl e ef fe ct s. Th er ef or e, t he i nd oo r un it
an d tu bi ng b et we en t he i nd oo r an d ou td oo r un it m us t be l ea k te st ed a nd e va cu at ed t o re mo ve
an y no nc on de ns ab le s an d mo is tu re f ro m th e sy st em .
Ch ec k th at e ac h tu be (b ot h li qu id a nd g as s id e tu be s) b et we en t he i nd oo r an d ou td oo r un it s ha ve
be en p ro pe rl y co nn ec te d an d al l wi ri ng f or t he t es t ru n ha s be en c om pl et ed .
Pi pe l en gt h an d re fr ig er an t am ou nt :
Outdoor
unit
Indoor
unit
Refrigerant
Packed valve
Half union
Gas side
Liquid side
A
C
D
B
1. C om pl et el y ti gh te n th e fl ar e nu ts , A , B, C , D, c on ne ct
t
he m an if ol d va lv e ch ar ge h os e to a c ha rg e po rt o f th e
p
ac ke d va lv e on t he g as p ip e si de .
2
. Co nn ec t th e ch ar ge h os e co nn ec ti on t o th e va cu um
p
um p.
3
. Fu ll y op en t he h an dl e Lo o f th e ma ni fo ld v al ve .
4
. Op er at e th e va cu um p um p to e va cu at e. Aft er s ta rt in g
e
va cu at io n, s li gh tl y lo os e th e fl ar e nu t of t he p ac ke d
v
al ve o n th e ga s pi pe s id e an d ch ec k th at t he a ir i s
e
nt er in g. ( Op er at io n no is e of t he v ac uu m pu mp c ha ng es
a
nd a c om po un d me te r in di ca te s 0 in st ea d of m in us )
5. Aft er t he e va cu at io n is c om pl et e, f ul ly c lo se t he h an dl
e
L
o of t he m an if ol d va lv e an d st op t he o pe ra ti on o f th e
v
ac uu m pu mp .
Ma ke e va cu at io n fo r 15 m in ut es a nd m or e an d ch ec k
5
th at t he c om po un d me te r in di ca te s -7 6c mH g( -1 .0 x1 0 Pa ).
O
6
. Turn t he s te m of t he p ac ke d va lv e B ab ou t 45 co un te r-
cl oc kw is e fo r 6~ 7 se co nd s af te r th e ga s co mi ng o ut , th en
ti gh te n th e fl ar e nu t ag ai n. M ak e su re t he p re ss ur e di sp la y
in t he p re ss ur e in di ca to r is a l it tl e hi gh er t ha n th e at mo sp he re
pr es su re .
7
. Re mo ve t he c ha rg e ho se f ro m th e Lo w pr es su re c ha rg e ho se .
8
. Fu ll y op en t he p ac ke d va lv e st em s B an d A .
9
. Se cu re ly t ig ht en t he c ap o f th e pa ck ed v al ve .
Manifold valve
Compound meter
-76cmHg
Handle Lo
Handle Hi
Charge hose
Charge hose
V acuum pump
Pressure gauge
Packed valve
Pe rf or m te st o pe ra ti on a ft er c om pl et in g ga s le ak c he ck a t th e fl ar e nu t co nn ec ti on s an d el ec tr ic al
sa fe ty c he ck .
Ch ec k th at a ll t ub in g an d wi ri ng h av e be en p ro pe rl y co nn ec te d.
Ch ec k th at t he g as a nd l iq ui d si de s er vi ce v al ve s ar e fu ll y op en .
1. C on ne ct t he p ow er, pr es s th e ON /O FF b ut to n on t he r em ot e co nt ro ll er t o tu rn t he u ni t on .
2. U se t he M OD E bu tt on t o se le ct C OO L, H EAT , A UTO a nd FAN t o ch ec k if a ll t he f un ct io ns w or ks
we ll .
O
3. Wh en t he a mb ie nt t em pe ra tu re i s to o lo w( lo we r th an 1 7 C) , th e un it c an no t be c on tr ol le d by t he
re mo te c on tr ol le r to r un a t co ol in g mo de , ma nu al o pe ra ti on c an b e ta ke n. M an ua l op er at io n is
us ed o nl y wh en t he r em ot e co nt ro ll er i s di sa bl e or m ai nt en an ce n ec es sa ry.
Ho ld t he p an el s id es a nd l if t th e pa ne l up t o an a ng le u nt il i t re ma in s fi xe d wi th a c li ck in g so un d.
Pr es s th e Ma nu al c on tr ol b ut to n to s el ec t th e A UT O or C OO L, t he u ni t wi ll o pe ra te u nd er F or ce d
AU TO o r CO OL mod e( se e Us er M an ua l fo r de ta il s) .
4. Th e te st o pe ra ti on s ho ul d la st a bo ut 3 0 mi nu te s.
1 . A i r p u r g i n g
2 . W h e n u s i n g t h e V a c u u m P u m p
4 . T e s t r u n n i n g
3 . S a f e t y a n d l e a k a g e c h e c k
A: L o pa ck ed v al ve B : Hi p ac ke d va lv e
C an d D ar e en ds o f in do or u ni t co nn ec ti on .
CA U TI ON
1. S oa p wa te r me th od :
Ap pl y a so ap w at er o r a li qu id n eu tr al d et er ge nt o n th e in do or
un it c on ne ct io ns a nd o ut do or u ni t co nn ec ti on s by a s of t br us h
to c he ck f or l ea ka ge o f th e co nn ec ti ng p oi nt s of t he p ip in g. I f
bu bb le s co me o ut , it i nd ic at es t ha t th e pi pe s ha ve l ea ka ge .
2. Le ak d et ec to r
Us e th e le ak d et ec to r to c he ck f or l ea ka ge .
C ON N E CT T H E C AB L E TO T H E O UT D O OR U N IT
CAUTION
Indoor unit
check point
D
B
C
A
Outdoor unit
check point
Cover
Electrical box
cover
Front Panel
Ma nu al co nt ro l
bu tt on
AUTO/COOL
,
C o n n e c t t h e c a b l e t o t h e i n d o o r u n i t
Be fo re p er fo rm in g an y el ec tr ic al w or k, t ur n of f th e ma in p ow er t o th e sy st em .
1. T he i ns id e an d ou ts id e co nn ec ti ng c ab le c an b e co nn ec te d wi th ou t re mo vi ng t he f ro nt g ri ll e.
2. T he i nd oo r po we r co rd t yp e is H 05 VV-F o r H0 5V 2V 2- F , th e ou td oo r po we r co rd a nd
in te rc on ne ct ed c or d ty pe i s H0 7R N- F .
3. L if t th e in do or u ni t pa ne l up , re mo ve t he e le ct ri ca l bo x co ve r by l oo se ni ng t he s cr ew.
4. E ns ur e th e co lo ur o f wi re s of o ut do or u ni t an d th e te rm in al N os . ar e th e sa me t o th e in do or s
re sp ec ti ve ly.
5. W ra p th os e ca bl es n ot c on ne ct ed w it h te rm in al s wi th i ns ul at io n ta pe s, s o th at t he y wi ll n ot t ou ch
an y el ec tr ic al c om po ne nt s. S ec ur e th e ca bl e on to t he c on tr ol b oa rd w it h th e co rd c la mp .
N O T E :
NOTE: If used as MONO unit, for the standby control needs, the cross section area of cable connected
to L(1), 1, 2(N) must be sufficient for the maximum system current. The maximum system current is
equal to the sum of indoor unit and outdoor unit rated current.
T erminal block of indoor unit
T o outdoor unit
L(1)
2(N)
S
1
1. Rem ov e t he ele ct ri ca l c on tr ol boa rd cov er fro m t he out do or uni t b y l oo se ni ng the scr ew.
2. Con ne ct the con ne ct iv e c ab le s t o t he ter mi na ls as i de nt if ie d w it h t he ir re sp ec ti ve mat ch ed num be r
s
on the ter mi na l b lo ck of i nd oo r a nd out do or uni ts .
3. Sec ur e t he cab le ont o t he con tr ol boa rd wit h t he cor d c la mp .
4. T o p re ve nt th e i ng re ss of wat er, f or m a loo p o f t he co nn ec ti ve cab le as i ll us tr at ed in t he ins ta ll at io n
di ag ra m o f i nd oo r a nd out do or uni ts .
5. Ins ul at e u nu se d c or ds (co nd uc to rs ) w it h P VC -t ap e. Pro ce ss the m s o t he y d o n ot to uc h a ny ele ct ri ca
l
or met al par ts .
Cover
Screw
T erminal block of outdoor unit
T o indoor unit
Power supply
1
2(N)
S
L N
L(1)
I
N
D
O
O
R
U
N
I
T
C ON N E CT T H E C AB L E TO T H E I ND O O R UN I T
4
In st al l th e ou td oo r un it o n a ri gi d ba se t o pr ev en t in cr ea si ng n oi se l ev el a nd v ib ra ti on .
De te rm in e th e ai r ou tl et d ir ec ti on w he re t he d is ch ar ge d ai r is n ot b lo ck ed .
In t he c as e th at t he i ns ta ll at io n pl ac e is e xp os ed t o st ro ng w in d su ch a s a se as id e, m ak e
su re t he f an o pe ra ti ng p ro pe rl y by p ut ti ng t he u ni t le ng th wi se a lo ng t he w al l or u si ng a d us t
or s hi el d pl at es .
Sp ec ia ll y in w in dy a re a, i ns ta ll t he u ni t to p re ve nt t he a dm is si on o f wi nd . If n ee d su sp en di ng
in st al la ti on , th e in st al la ti on b ra ck et s ho ul d ac co rd w it h te ch ni qu e re qu ir em en t in t he
in st al la ti on b ra ck et d ia gr am . Th e in st al la ti on w al l sh ou ld b e so li d br ic k, c on cr et e or t he s am e
in te ns it y co ns tr uc ti on , or a ct io ns t o re in fo rc e, d am pi ng s up po rt in g sh ou ld b e ta ke n.
Th e co nn ec ti on b et we en b ra ck et a nd w al l, b ra ck et a nd t he a ir c on di ti on er s ho ul d be f ir m,
st ab le a nd r el ia bl e.
Be s ur e th er e is n o ob st ac le w hi ch b lo ck r ad ia ti ng a ir.
S tr o n g
w in d
S tr o n g
w in d
B ar r i e r
I n c or r e c t
C o r re c t
Se al
Dr ai n joi nt
Ba se p an ho le
of o ut doo r un it
( A )
( B )
Th e dr ai n jo in t is s li gh tl y di ffe re nt a cc or di ng t o th e
di ff er en t ou td oo r un it .
Fo r th e dr ai n jo in t wi th t he s ea l( Fi g. A) , fi rs t fi t th e se al o nt o
th e dr ai n jo in t, t he n in se rt t he d ra in j oi nt i nt o th e ba se p an
。
ho le o f ou td oo r un it , ro ta te 9 0 to s ec ur el y as se mb le t he m.
T o in st al l dr ai n jo in t as s ho wn i n Fi g. B, i ns er t th e dr ai n
jo in t in to t he b as e pa n ho le o f ou td oo r un it u nt il i t re ma in s
fi xe d wi th a c li ck in g so un d. C on ne ct in g th e dr ai n jo in t wi th
an e xt en si on d ra in h os e (L oc al ly p ur ch as ed ), i n ca se o f th e
wa te r dr ai ni ng o ff t he o ut do or u ni t du ri ng t he h ea ti ng m od e.
2
D RA I N J OI N T IN S T AL L A TI O N
O UT D O OR I N SA L L AT I O N PR E C AU T IO N
3
Oblique
O
90
Roughness
Burr
R EF R I GE R AN T P I PE C O N NE C TI O N
1. C ut a p ip e wi th a p ip e cu tt er.
2
. Re mo ve f la re n ut s at ta ch ed t o in do or a nd
o
ut do or u ni t, t he n pu t th em o n pi pe /t ub e
h
av in g co mp le te d bu rr r em ov al a nd f la re
t
he p ip e.
3
. Fi rm ly h ol d co pp er p ip e in a d ie i n th e
d
im en si on s ho wn i n th e ta bl e be lo w.
.
.
Al ig n pi pe s to b e co nn ec te d.
Su ff ic ie nt ly t ig ht en t he f la re n ut w it h fi ng er s,
an d th en t ig ht en i t wi th a s pa nn er a nd t or qu e
wr en ch a s sh ow n.
Ex ce ss iv e to rq ue c an b re ak n ut d ep en di ng
on i ns ta ll at io n co nd it io ns .
Outer diam.
(mm)
A(mm)
Max.
Min.
6.35 1.3
0.7
9.52
1.6 1.0
12.7
1.8 1.0
12.7
16
1.8
2.2
1.0
2.0
Bar
Copper pipe
Clamp handle
Handle
Bar
"A"
Indoor unit tubing Flare nut Pipings
.
Outer
diam.
T ightening
torque(N.cm)
Additional tightening
torque(N.cm)
φ6.35mm
φ12.7mm
φ16mm
φ9.52mm
1500
(153kgf.cm)
1600
(163kgf.cm)
3500
(357kgf.cm)
4500
(459kgf.cm)
3600
(367kgf.cm)
4700
(479kgf.cm)
2500
(255kgf.cm)
2600
(265kgf.cm)
F l a r i n g
T i g h t e n i n g c o n n e c t i o n
O
U
T
D
O
O
R
U
N
I
T
1
NO TE :
El ec tr ic saf et y r eg ul at io ns for the ini ti al Ins ta ll at io n
1. If t he re is s er io us saf et y p ro bl em abo ut the pow er sup pl y , the tec hn ic ia ns sho ul d r ef us e t o i ns ta ll
th e a ir con di ti on er and exp la in to t he cli en t u nt il the pro bl em is s ol ve d.
2. Pow er vol ta ge sho ul d b e i n t he ran ge of 9 0% ~110% o f ra te d v ol ta ge .
3. Th e s ur ge pr ot ec to r a nd ma in pow er swi tc h w it h a 1.5 tim es cap ac it y o f M ax . C ur re nt of the uni t s ho ul d
be ins ta ll ed in p ow er cir cu it . E ns ur e t he air con di ti on er is g ro un de d w el l.
4. Th e a pp li an ce sh al l b e i ns ta ll ed in acc or da nc e w it h n at io na l w ir in g r eg ul at io ns . D o n ot op er at e y ou r a ir
co nd it io ne r i n a wet roo m s uc h a s a ba th ro om or l au nd ry roo m.
5. An all -p ol e d is co nn ec ti on dev ic e w hi ch has at l ea st 3mm cle ar an ce s i n a ll pol es , a nd ha ve a le ak ag e
cu rr en t t ha t m ay exc ee d 1 0m A, the res id ua l c ur re nt dev ic e( RC D) hav in g a rat ed res id ua l o pe ra ti ng
cu rr en t n ot exc ee di ng 30m A, and dis co nn ec ti on mus t b e i nc or po ra te d i n t he fix ed wir in g i n a cc or da nc e
wi th the wir in g r ul es .
6. For the uni t a do pt s a ux il ia ry ele ct ri c h ea te r, ke ep at l ea st 1 m et er awa y f ro m t he nea re st com bu st ib le
ma te ri al s.
7. Ac co rd in g t o t he att ac he d E le ct ri ca l C on ne ct io n D ia gr am lo ca te d o n t he pan el of t he ind oo r & out do or
un it to c on ne ct the wir e. Al l w ir in g m us t c om pl y w it h l oc al an d n at io na l e le ct ri ca l c od es and be i ns ta ll ed
by qua li fi ed and ski ll ed ele ct ri ci an s.
8. An ind iv id ua l b ra nc h c ir cu it and sin gl e r ec ep ta cl e u se d o nl y f or th is air con di ti on er mus t b e a va il ab le .
Se e t he fol lo wi ng tab le for sug ge st ed wir e s iz es and fus e s pe ci fi ca ti on s:
M i n i m u m c r o s s - s e c t i o n a l a r e a o f c o n d u c t o r s :
R a t e d c u r r e n t
o f a p p l i a n c e
( A )
>3 and ≤6
>6 and ≤10
>10 and ≤16
>16 and ≤25
>25 and ≤32
>32 and ≤40
N o m i n a l c r o s s - s e c t i o n a l
a r e a
( m m 2 )
0.75
1
1.5
2.5
4
6
E l e c t r i c a l w o r k
Th e w ir e s iz e o f p ow er su pp ly cor d a nd
in te rc on ne ct ed wi re and the cur re nt of
th e f us e o r s wi tc h a re de te rm in ed by the
ma xi mu m c ur re nt in di ca te d o n t he
na me pl at e w hi ch lo ca te d o n t he si de pan el
of the uni t. Ple as e r ef er to the nam ep la te
be fo re sel ec ti ng th e w ir e s iz e, fu se or s wi tc h.
Th e c on tr ol le r o f t he ai r c on di ti on er de si gn ed
wi th a fu se pro te ct io n f un ct io n u nd er
ab no rm al con di ti on s, th e s pe ci fi ca ti on s o f
th e f us e h av e p ri nt ed on the cir cu it boa rd ,
su ch as: 3.1 5A /2 50 V A C, T5 A/ 25 0VAC, etc .
N O T E :
N O T E :
C o n n e c t i v e p i p e l e n g t h w i l l a f f e c t t h e c a p a c i t y a n d e n e r g y e ff i c i e n c y o f t h e u n i t . T h e
n o m i n a l e f f i c i e n c y i s t e s t e d b a s i n g o n t h e p i p e l e n g t h o f 5 m e t e r s .