Parameter 4: Humidity Delta Level
This is the humidity Delta Level which determines when to report the current humidity value.
Size: 1 Byte, Default Value: 0
Setting Description
0Indicates Turn off report
1 - 127 Indicates to report current humidity value when change >n%
Parameter 5: VOC Delta Level
This is the VOC Delta Level which determines when to report the current VOC value.
Size: 1 Byte, Default Value: 0
Setting Description
0Indicates Turn off report
1 - 127 n*5ppb Report change
Parameter 6: Lux Delta Level
This is the brightness Delta Level which determines when to report the current brightness value.
Size: 2 Byte, Default Value: 0
Setting Description
0Indicates Turn off report
1 - 32767 Indicates to report current Illumination value when change >n*1 Lux
Parameter 7: dB Delta Level
This is the noise Delta Level which determines when to report the current noise value.
Size: 1 Byte, Default Value: 0
Setting Description
0Indicates Turn off report
1 - 127 Indicates to report current Noise value when change >n*1 dB
Parameter 8: PIR Delta Level
This is the temperature Delta Level which determines when to report the current temperature value.
Size: 1 Byte, Default Value: 0
Setting Description
0Indicates Turn off report
1Indicates report change
Parameter 9: SMOKE Delta Level
Size: 1 Byte, Default Value: 1
Setting Description
0Indicates Turn off report
1Indicates report change
Parameter 10: Smoke Timer
Size: 2 Byte, Default Value: 60
Setting Description
0Turn off report
35 - 32767 Report every n*1s
Parameter 11: PIR Timer
Size: 2 Byte, Default Value: 60
Setting Description
0Turn off report
35 - 32767 Report every n*1s