15
3-INSTALLATION AND ASSEMBLY
TECHNICAL CHARACTERISTICS BOXTHERM 70 PELLET
Nominal output power: 8,8 kw (7568 kcal/h)
Minimum output power: 2,6 kw (2236 kcal/h)
Eciency at Max 92,7%
Eciency at Min 95,9%
Temperature of exhaust smoke at Max 150 °C
Temperature of exhaust smoke at Min 70 °C
Particulate/OGC/Nox (13% O
2
) 16,5 mg/Nm
3
- 6 mg/Nm
3
- 125
mg/Nm
3
CO at 13% O
2
at Min and at Max 0,030 – 0,015%
CO
2
at Min and at Max 5,5% - 8,4%
Recommended draught at Max power 0,10 mbar - 10 Pa
Recommended draught at Min power 0,05 mbar - 5 Pa
Mass of smoke 7,4 g/sec
Hopper capacity 27 litres
Type of pellet fuel Pellet diameter 6-8 mm and size 5/30 mm
Pellet hourly consumption Min ~ 0,6 kg/h* - Max ~ 1,8 kg/h*
Autonomy At min ~ 26 h* - At max ~ 9 h*
Heatable volume m
3
189/40 – 216/35 – 252/30 **
Combustion air inlet External diameter 50 mm
Smoke outlet External diameter 80 mm
Air inlet 80 cm
2
Nominal electrical power (EN 60335-1) 80 W (Max 420 W)
Supply voltage and frequency 230 Volt / 50 Hz
Net weight 135 kg
Weight with packaging 145 kg
* These data may vary according to the type of pellets used.
** Heatable volume based on the requested power per m3 (respectively 40-35-30 Kcal/h per m3).
Tested according to EN 14785 in accordance with Directive 89/106/EEC (Construction Products).
Technical Dept. - All rights reserved - Reproduction is prohibited