PELLET STOVES Chapter 4
INSTALLATION AND USE MANUAL
page 47
Operation Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited
MESSAGE ON
DISPLAY
TYPE OF PROBLEM SOLUTION
A10
The plug is defective
Contact an authorized service centre to replace the
component.
A11
Defective pellet feeder
Contact an authorized service centre to replace the
component.
A12
The remote control has been beyond the
reception range of the stove for more than
three hours, or its batteries are dead.
NOTE: only in this case the stove does not go
into alarm shutdown, but continues operating
in the mode that the remote control set via the
last sent command.
Move the remote control back to within range of the
stove, or change the batteries if they are dead.
As soon as the stove receives a new signal from the
stove, the alarm indications will disappear. A easy way
to force a transmission to the stove is to press button 4.
his changes operating mode from manual to automatic
and vice versa.
A13
Generic failure of electronic control unit
Contact an authorized service centre to replace the
component.
A14
Generic failure of sensor
This alarm is not blocked, only a warning screen
appears. Contact an authorized service centre to
replace the component.
SEr
Periodic maintenance warning
If this flashing messages appears when lighting the
stove, it means that the hours of operation pre-set
before the maintenance have elapsed and a new
maintenance intervention is necessary. Contact a
specialist MCZ technician.