35
9-OPERATION
Technical Dept. - All rights reserved - Reproduction is prohibited
Load feed screw function
This function, which can only be turned on when the stove is o, is designed to load pellets into the loading system (feed screw). It should
be used whenever the pellet tank is empty (see alarm A02) to avoid a failed ignition (alarm A01) due precisely to the fact that there are
no more pellets in the tank.
Proceed as follows to activate the function:
• Set the rst selector to OFF
• Set the second selector to MED
• Make sure the word OFF appears on the display, as this function can only be activated when the stove is completely cold (o) and
the selector is set to OFF
• Press TEST 3 times within 2 seconds
• The display will show COC-LEA [FEED SCREW] in two subsequent intervals
• When the pellets start falling into the brazier, press TEST again to stop the LOAD FEED SCREW function or wait for the function to
stop on its own
• Turn the stove on.