PELLET STOVES Chapter 4
INSTALLATION AND USE MANUAL
page 32
Operation Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
4.9. HOT AIR VENTILATION
The KAIKA - FACE stove is equipped with an inner fan for the
expulsion of the hot heating air that can be adjusted indifferently if the
stove is in manual or automatic mode.
5 speeds can be selected
as well as an automatic function.
To select the speed, after pressing the bottom right button, press it
again to increase or decrease the fan power.
In addition to 5th speed there is an additional selection called AUTO
function. This function lets you connect the fan speed to the flame
power. With this option selected, the stove will independently select the
fan speed based on the flame power.
Such function allows ventilation speed to be "connected" to the flame
power with a maximum of V3. When such operation is selected the
stove shall independently select fan speed according to flame power up
to a maximum of V3 (P1=V1; P2=V2; P3=V3; P4=V3; P5=V3) to avoid
noise.
In order to prevent the structure from overheatin
low speeds when the stove is at
maximum performance.
4.10. Room sensor
The room probe (B) is located at the back of the stove; should this
be near the fumes exhaust tube, we recommend to extract the
room probe so that it sticks out by approximately 10 cm. In this way it
will not be affected by the tube's heat and the measured temperature
will be near to that of the room.
It is advisable to do this operation during installation, since before
extracting the probe (B) it is necessary to take off the clamp (C) that
keeps it connected; operation possible by working inside the stove thus
without the sides. To extract the probe (B) it is necessary to unscrew
the protection cap (A) and slowly pull the probe (B). After extracting
the probe (B) sufficiently, close the protection cap (A) again.
ATTENTION! Once the clamp that binds the probe
wire is taken off, avoid it coming into contact with the
hot parts of the stove.
Room temperature sensor