5.4.2. Automatic mode with AUTO-ECO (panel
display: ON-AUTO ECO)
Activation of this mode is performed through the MENU - SETTINGS -
AUTO ECO-ON.
As for AUTO mode, the desired room temperature is set; when the set
temperature < room temperature condition is reached (room
temperature achieved) the "ECO shutdown T" begins to decrease
(default 10 minutes, changeable within the technical menu by an
authorised MCZ technician). During this phase on the small panel
display remains ON-ECO ACTIVE, but the flame drops automatically by
one power per minute until it reaches P1 and stays there until the
programmed "ECO shutdown T" lapses and if the room temperature is
still achieved, it moves on to the shutdown phase.
ECO stop shutdown follows the normal shutdown procedure, whilst on
the penal the wordings "SHUTDOWN" and "ECO ACTIVE" alternate.
The possibility of adjusting "ECO shutdown T" derives from the
necessity of correct operation in the various environments in which a
stove may be installed and avoiding continuous shutdowns and
lightings in the case in which the room temperature is subject to
constant changes (air currents, low room insulation etc.)
Once the stove shutdown conditions are reached, on the panel the
words "OFF" and “ECO ACTIVE” alternate.