11-FIRST START-UP
Technical Dept. - All rights reserved - Reproduction prohibited
SWITCHING THE EQUIPMENT OFF
To switch o the appliance, press the button 1 on the emergency panel or the button 3 on the optional remote control.
The equipment will start the shutdown process which involves consuming the residual pellets in the brazier, the latter being cleaned and
the residual heat in the structure being dissipated.
During the residual heat dissipation phase, the fans operate at about 80% of their output and the speed cannot be varied. This is
determined by the need for all the accumulated heat to be evacuated safely and quickly. The shutdown stage can last 15 - 30 minutes
depending on the heat stored in the structure, determined by the duration and the operating speed of the product throughout the day.
When the internal temperature drops below the set thresholds, the fans for hot air and exhaust smoke extraction will automatically
switch o.
POWER SUPPLY
When ignition is complete, the panel will display ON with a steady ame at level 3 . The following ame modulation for higher or
lower power is then controlled autonomously based on reaching the set temperature.
(also see “OPERATING MODE” - “Set Flame”)
If the ame fails to ignite, despite a regular ow of pellets, check that the brazier is seated correctly: it must rest snugly against the
interlocking slot and be clean of any ash incrustations. If no anomaly is found during this inspection, there may be a problem with
the product components or installation may not be correct.
REMOVE THE PELLETS FROM THE BRAZIER AND CONTACT AN AUTHORISED TECHNICIAN.
Please ensure the brazier is clear of ALL pellets and ash build up following any failed ignitions. Failure to clear out
the brazier prior to resetting may result in further failed ignitions or explosive ignition under certain conditions.
It is good practice to ensure eective ventilation in the room during the initial ignition, as the product will emit some
smoke and smell of paint.
Do not stand close to the product and ventilate the room as mentioned. The smell of paint will disappear after about an hour of operation,
however, it is not harmful in any case.
The product will be subject to expansion and contraction during the ignition and cooling stages, therefore slight creaking noises may be
heard.
This is perfectly normal as the structure is made of laminated steel and must not be considered a defect.
DO NOT EXPECT HEATING EFFICIENCY IMMEDIATELY!!! THE PRODUCT NEEDS SOME RUNNING-IN TIME.
It is extremely important to make sure the product does not reach high temperatures straight away, but to increase the temperature
gradually using low power at rst.
This will prevent damage to the welds and to the steel structure.
Do not touch the product during the rst lighting, as it is during this stage that the paint sets. If you touch the paint,
you may expose the steel surface.
If required, touch up the paint with the spray can of the specic colour.
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für MCZ MIDA AIR 8 XUP S1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von MCZ MIDA AIR 8 XUP S1

MCZ MIDA AIR 8 XUP S1 Bedienungsanleitung - Deutsch - 32 seiten

MCZ MIDA AIR 8 XUP S1 Installationsanweisung - Deutsch - 52 seiten

MCZ MIDA AIR 8 XUP S1 Installationsanweisung - Englisch - 52 seiten

MCZ MIDA AIR 8 XUP S1 Bedienungsanleitung - Holländisch - 32 seiten

MCZ MIDA AIR 8 XUP S1 Installationsanweisung - Holländisch - 52 seiten

MCZ MIDA AIR 8 XUP S1 Bedienungsanleitung - Französisch - 32 seiten

MCZ MIDA AIR 8 XUP S1 Installationsanweisung - Französisch - 52 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info