PELLET STOVES Chapter 5
INSTALLATION AND USE MANUAL
page 64
Maintenance and cleaning Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
21.0°C 21.04
OFF
B
A
A
D
D
5.1.3. Clean the exchanger and the undergrate space every 2/3 days.
Cleaning the exchanger and the undergrate space is a simple operation
but very important for always maintaining performance as declared by
MCZ.
Therefore we recommend cleaning the internal exchanger every 2-3
days, performing these simple operations in sequence:
o Activate the "CLEANING" function – when the stove is
off, press the key in the control panel highlighted in figure 14
for 2 seconds. This procedure activates the smoke suction fan
at maximum power in order to expel the soot which is moved
around whilst cleaning the exchanger.
o Remove the top
o Clean the pipe unit – Using the cool hand hook supplied,
energetically shake the rods located under top A in figure 15)
5-6 times.. This operation removes soot deposited in the
exchanger's smoke ducts when the stove is working normally.
o Clean the smoke conveyor well
EGO-STAR stoves (Figure 15)
– Open the door and screw the cool hand to the scraper rod B
(B in figure15), shake it energetically 5-6 times throughout its
length. Unscrew the cool hand and reinsert rod B completely
into its housing. By doing so the fan is assisted in expelling any
accumulations of soot which fell when the pipe unit was
cleaned previously (After shaking rods “A” it is always
necessary to do so with scraper B”).
SUITE-CLUB-MUSA stoves (Figure 15A)
– The Suite-Club-Musa stoves are equipped with a removable
ash drawer to collect any build-ups of soot and ashes. To clean
the smoke conveyor well with the “CLEANING” function
activated, the ash drawer and the door must stay shut..
After activating the “CLEANING” function on the control
panel, remove the turbulators “D” and using a rigid rod, clean
the pipe unit.
o Deactivate the "CLEANING" function by pressing the
control panel key highlighted in figure 14 once again.
o Replace the top
If such cleaning is not done every 2-3 days the stove
could go into alarm caused by ash clogging after
several hours of operation.
Figure 14 – “Cleaning” function
Figure 15 - Cleaning the internal pipe
unit using scrapers (EGO-STAR)
Figure 15 - Cleaning the internal pipe
unit using scrapers (SUITE-CLUB-
MUSA)