PELLET STOVES Chapter 4
INSTALLATION AND USE MANUAL
page 51
Operation Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
Esc Set
< Date setting >
21.0°C 21.04
OFF
Mode:AUTO Menu
Temp:22°C Fan:A
Esc Set
< Setting >
Esc Set
< Auto-Eco >
Esc ON OK
< Auto-Eco >
21.0°C 21.04
OFF
Mode:ECO Menu
Temp:22°C Fan:1
Mode:ECO Menu
Temp:22°C Fan:1
4.9.3.1.
Activation /de-activation of AUTO-ECO mode
This mode makes it possible to optimize stove consumption in well-
insulated rooms.
When this option is activated, on the display of the control panel the
word AUTO-ECO will appear.
The display of the remote control will show the message AUTO along
with the message AUTO-ECO.
From the first screen with the word OFF, press any key and the screen
with the word MENU will appear.
With the bottom right button scroll until the word SETTINGS, press the
top left key SET, scroll with the bottom right key until the word AUTO-
ECO appears. Select SET again in the top right and with the bottom
right key set OFF or ON and press OK to save the setting. Now going
back to the initial menu you notice that the setting on the Mode is ECO.
Therefore, using the bottom left or bottom right keys it is possible to
set the temperature and the fan speed respectively, for the expulsion of
hot air.
To disable the AUTO-ECO function follow the same procedure.
Example of operation in AUTO-ECO mode
If the room temperature detected by the sensor and highlighted on the
control panel is 15°C and the set temperature is 20°C, the stove will
follow a pre-established ramp up to the 5
th
power. Once 20°C is
reached, it will go into standby mode (STANDBY).
When the room temperature drops below the value set on the control
panel (for example 18°C) and a sufficient shutdown time has elapsed,
the stove will come back on automatically and continue running until
again reaching 20°C. If the temperature read by the room sensor
remains above the value set on the thermostat (for example 20-21°C)
the stove will remain off.
In this mode, lighting can be carried out by the user by resetting the
thermostat temperature to a value greater than that in the room, or by
shutting down the stove by pressing button B for a few seconds and
then pressing the same button to re-light the stove.
The “AUTO-ECO” mode does not need to be reset as it remains in
memory from the last use.