Read the instruction manual carefully before using this
device, especially the safety instructions, and keep the in-
struction manual for future use. Should you give this device
to another person, it is vital that you also pass on these in-
structions for use.
EN Safety instructions
Intended use
The product is used exclusively for giving aroma to the air in dry, closed indoor rooms. The
product is not intended for commercial use but rather only domestic use. Intended use also
includes compliance with all information and specications contained in these operating instruc-
tions. Any use other than for its intended purpose shall be deemed as misuse.
Misuse
Misuse of the product can lead to hazardous situations.
Fill the product only with water or aromatic water and use no other liquids.
Do not use the product in wet rooms, such as bathrooms or saunas.
Do not use the product in rooms with open re (replace, gas cooker, candles etc.).
Do not insert any objects into the openings of the product.
Do not place the product directly in front of an air conditioning unit or other electrical de-
vices.
The device must be used only with the adaptor (ICP12-240-0500D) supplied with the ap-
pliance.
Children
This device can be used by children of 8 years of age and above and by persons with re-
stricted physical, sensory or mental capacity or lack of experience and knowledge if they
are supervised or have been instructed on the safe use of the device and understand the
resultant hazards.
Make sure that the product is set up out of the reach of children.
Make sure that children are not allowed to play with the product at any time.
Cleaning and user maintenance must not be performed by children without supervision.
Do not leave packaging material lying around unattended. There is a risk of asphyxiation.
Improper handling
Improper handling of the product can cause injuries.
Make sure that the product is connected properly. In the process, adhere to these operating
instructions.
Make sure that the product is used properly. Never cover it.
Be aware that unauthorised conversion and / or modication of the product is prohibited. In
case of unauthorised conversion and / or modication the warranty cover will be rendered
null and void.
Never open the water tank during operation.
Before lling or emptying the product, always pull the mains plug from the socket.
Before installation, cleaning or a period in which the product is not used, pull the mains from
the socket.
Empty the water tank before a period in which the product is not used.
Contact the manufacturer or a specialist if you have any doubts regarding the way the pro-
duct works, its safety or how to connect the product.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualied persons in order to avoid a hazard.
Setting up
If liquids, damp air or re come into contact with the product, there is
a risk of injuries.
Do not set up the product in rooms with high air humidity, such as bathrooms or saunas.
Make sure that no liquids enter into the inside of the housing. This will not only destroy the
product but there is also a risk of re.
Protect the product from the effects of the elements. Do not set it up outdoors.
Only ever place the product on at surfaces. If placed on an inclined surface, water from the
water tank may enter into the housing.
Make sure that the air inlet openings on the base of the product are not covered or sealed.
Usage
The appliance is only to be used with the recommended vaporizing medium. The use of other
substances may give rise to a toxic or re risk.
Be aware that high humidity levels may encourage the growth of biological organisms in the
environment.
Do not permit the area around the humidier to become damp or wet. If dampness occurs,
turn the output of the humidier down. If the humidier output volume cannot be turned down,
use the humidier intermittently. Do not allow absorbent materials, such as carpeting, curtains,
drapes, or tablecloths, to become damp.
Unplug the appliance during lling and cleaning.
Never leave water in the reservoir when the appliance is not in use.
Empty and clean the humidier before storage. Clean the humidier before next use.
Warning: Micro-organisms that may be present in the water or in the environment where the
appliance is used or stored, can grow in the water reservoir and be blown in the air causing
very serious health risks when the water is not renewed and the tank is not cleaned properly
every 3 days.
Device and controls
1 mist outlet
2 removable water tank cover
3 device socket
4 on/off button
The Aroma Diffuser is controlled by the On/Off button 4. This button can be
used to switch the Aroma Diffuser on and off. It can only be switched on when
the water tank is correctly lled (max. lling quantity 100 ml). 100 ml water will
provide approx. 4 hours of continuous use. Device will auto off when tank is
empty.
Filling the water tank with water and aroma essence
Remove the tank cover 2 upwards from the unit.
Fill the water tank with max. 100 ml of fresh drinking water. Then add a few
drops of the aroma essence (depending on the desired intensity) to the water
tank lled with max. 100 ml.
ATTENTION! Make sure that the device is operated on a surface which is
resistant to water, and that it cannot tip over. In particular, when operated with
mineralised water, condensation / residues may be produced. Make sure that
the mist being issued is not directed towards electronic appliances, furniture or
walls.
Disposal
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be disposed
of in an environmentally acceptable manner. Consult your municipal authority or
your dealer for information about disposal.
Technical specications
Name and model :
Current supply :
Consumption :
Dimensions :
Weight :
Water tank capacity :
Item number :
EAN number :
The current version of this instruction manual can be found under www.medisana.com
In accordance with our policy of continual product improvement, we re-
serve the right to make technical and visual changes without notice.
medisana Aroma diffuser AD 100
100 - 240 V~, 50/60 Hz
24 V 0.5 A
7 Watt
approx. 103 x 103 x 174 mm
approx. 427 g
100 ml
60081
40 15588 60081 4
DE/EN
EN INSTRUCTION MANUAL Aroma diffuser AD 100
Cleaning and maintenance
Before cleaning, pull the mains plug.
Empty the device after each use and dry the water tank with a cloth.
Wash the water tank with clear water when you wish to change the aroma.
This prevents mixing different aromas.
Only clean the outside of the device with a soft, slightly damp cloth. Then rub it
dry with a soft, dry cloth.
Do not under any circumstances us brushes, sharp cleaning implements, ben-
zene, thinners or alcohol.
Descaling
Descale the device after ve or six uses or every 14 days. To do so, proceed as
follows:
1. Disconnect the device from the power supply.
2.
Fill the water tank with a maximum of 10 ml and add three tablespoonfuls of citric
acid.
3. Allow the liquid to take effect for at least fteen minutes.
4. Empty out the liquid.
5. Rinse the water tank with fresh water.
6. Wipe out the water tank with a dry cloth.
However, if you have any questions, please contact our service department.
Explanation of symbols
IMPORTANT
Non-observance of these instructions can
result in serious injury or damage to the
device.
WARNING
These warning notes must be observed
to prevent any injury to the user.
CAUTION
These notes must be observed to prevent
any damage to the device.
NOTE
These notes give you useful additional in-
formation on the installation or operation.
Only use the device indoors.
Protection category II
Lot number
Manufacturer
ATTENTION! Make sure that the device
is operated on a surface which is resist-
ant to water, and that it cannot tip over.
In particular, when operated with miner-
alised water, condensation / residues
may be produced. Make sure that the
mist being issued is not directed to-
wards electronic appliances,
furniture or walls.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the warranty. If you have
to return the unit, please enclose a copy of your receipt and state what the defect is.
The following warranty terms apply:
1. The warranty period for medisana products is three years from date of purchase. In case of a
warranty claim, the date of pur chase has to be proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within the warranty period.
3. Repairs under warranty do not extend the warranty period either for the unit or for the replace-
ment
parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g. non-observance of the user instruc-
tions.
b. All damage which is due to repairs or tampering by the customer or unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to the consumer or during
transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused
medisana GmbH, Carl-Schurz-Str. 2, 41460 NEUSS, GERMANY
1
2
Choose mains plug that ts your mains so-
cket and mount it to the adapter.
Connect plug to device socket 3 and plug in
adapter to the mains socket.
3
100 ml
1
2
43
maximal ll height
2

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Medisana AD 100 - Aroma Diffusor wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info