507947
27
Zoom out
Zoom in
Vorherige Seite
1/46
Nächste Seite
26
27
USING THE APPARATUS
The appliance is used for light therapies that counteract
winter fatigue, which can cause the following
symptoms:
• fatigue
• badmoodormoodiness
• lackofenergy
• increasedneedforsleep
• lackofconcentration
• lackofappetite
Over 60% of the population are believed to experience
one or more symptoms of winter blues due to the low
intensity of the winter sun.
The most effective time of day to take a light therapy is
between 6 am and 8 pm for a recommended period of
2 hours per day.
You can take light therapies as often as you like but the
treatment is most effective if you take light therapies
ofthebelow-mentioneddurationatleastvedaysin
a row.
Positioning the appliance
• Unfoldthestand(4)atthebackoftheappliance
and place the appliance on a table.
or
• Mounttheapplianceonthewallusingtheenclosed
wallbrackets.Checkbeforemountingthatthe
wall and the screws can carry the weight of the
appliance.
Use
• Inserttheplug(8)inthemainssocketandswitchon
the power.
• Switchontheon/offbutton(5).
• Sitdowninfrontoftheapplianceinapositionwhere
you can comfortably see the light and with your face
20-60 cm from the screen (2). You do not need to sit
directly in front of the screen.
• Thedurationofthelighttherapydependsonyour
distancefromthescreen:
Distance to screen Max duration of light therapy
60 cm Approx. 2 hours
40 cm Approx. 1 hour
20 cm Approx. ½ hour
• Thelighttherapycanbeinterruptedandyoucan
do other things at the same time (e.g. read or watch
television) as long as you sit within 60 cm from the
appliance.
• Donotlookdirectlyintothelightconstantly,but
look at it regularly.
• Alwaysturnofftheapplianceusingtheon/off
button, and unplug it, when it is not in use.
• Allowtheappliancetocoolforatleast15minutes
before putting it away or moving it.
TIP:Carrytheappliancebythecarryinghandleonthe
top of the rear part (3).
REPLACEMENT OF FLUORESCENT TUBES AND
STARTING SWITCH
Thelifetimeoftheuorescenttubesisapprox.8,000
hours of normal use. If a tube fails, it must be replaced.
• IMPORTANT!Discarduseduorescenttubesin
accordance with the rules for environmentally
harmful waste, e.g. by taking them to a waste
recovery site.
How to dismantle the appliance
• IMPORTANT!Alwaysmakesuretoswitchoffthe
appliance and remove the plug from the mains
socket before taking it apart to avoid the risk of
electric shocks.
• Placetheapplianceonanon-scratchingsurface,
screen down.
• Removethetopcover(1)byunfasteningitwithyour
ngers,rstinonesideandthenintheother.
• Removethetwoscrewsatthetopofthestand
using a Phillips screwdriver.
• Removethetwoscrewsintherearbase(7),and
carefully loosen the rear and front parts of the base
(6) from the rest of the appliance.
o IMPORTANT!Verycarefullydetachthetwobase
parts, since they are connected to the rest of the
appliance with cords that must not be damaged.
• Removethe9screwsalongthesideoftherearpart.
o The screws of the appliance may be of different
types. Therefore, pay attention to which screws
belong to the different screw holes in order to
place them correctly when reassembling the
appliance.
• Carefullyremovetherearpart,turnitupsidedown
and put it down in front of you.
• Replacethestartingswitch(ifapplicable):
o Turn the starting switch (b) anti-clockwise and
remove it.
o Insert a new starting switch of the same type
and turn it clockwise until it locks into place.
• Replacetheuorescenttubes:
o Remove the
locking clip (d) by
pushing the ends
upwards until they
click into place and
remove the clip.
o Grip the socket
oftheuorescent
tube (a) and pull
the tube out of the socket (towards the top of
the appliance).
o Insertanewuorescenttubeinthesocketasfar
as it goes until it clicks into place.
o Press the locking clip onto the holder (c) until it
clicksintoplace.Checkthattheuorescenttube
isttedcorrectly.
o IMPORTANT!Replacetheuorescenttubeswith
tubes of the same type. Always replace both
tubes at the same time.
27

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Melissa FOTOTHERAPIE 16780007 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info