Please read these instructions thoroughly , before using the UV-C unit! Otherwise you may not use
it!
This appliance is not suitable for use by persons (including childr en) with limited physical, sensory or mental
capabilities or lacking experience and/or knowledge , ex cept if they are supervised by a person responsible
for their safe t y or hav e been instructed in the use of the appliance .
Children should be supervised in order to make sure tha t they do not play wit h the appliance.
Use
This UV - C unit is suitable for use in garden or fi sh ponds helping to clear pollut ed pond water .
It is not allowed t o use the unit in or on the side of swimming pools!
Please refer to the type plate for technical specifi cations or the table on pag e 1 .
Safety measures
- Cautio! UV -C radiation is dangerous to eyes and skin!
Do operate the UV-C unit only inside the casing.
T ranslucent connections allow you t o check easily and safely that the unit is working properly .
- It ma y only be used in garden ponds and in their protection area , if the installations ha ve been set up t o
comply with the code’s r equirements. Please contact an electrician.
- The UV-C unit has to be connected to a regular safety plug socket through a circuit breaker
(ground fault circuit interruptor , 30 mA).
- Before use: Check whether mains connection and electrical box ar e intact.
- The mains c onnection of the electrical box cannot be replaced . If the c onnection is damaged the device
has to be scrapped.
- If the mains c onnection between electrical box and UV -C unit is damaged it must be replaced by the
manufacturer or his customer service or similarly qualifi ed personnel in order to av oid dangers.
- Mains voltage and type of current have to correspond t o the data on the type plate of the electrical box .
- The connection bo x and the UV - C unit should be located in a w aterprotected are a. They should be a t
least 3,5 m awa y from the edge of the pond (see fi g. A + B)
- K eep the plug dry!
- Pull out mains plug before star ting to work on the UV -C unit, garden or fi sh pond. (Disconnect the
electrical box.)
- It is not allowed to run the UV-C unit when people are inside the water!
- Do never immerse the UV -C unit in water and make sur e that the unit ma y not be fl ooded.
- Do never hang up or transport the UV-C unit by the cables .
- Avoid e xposure to intense sunlight.
Start-up (see fi g. A - C)
Important! Make sure that water alway s passes through the UV-C unit during operation. Otherwise
the unit could be damaged.
- Y ou should only connect a pump with a max.
delivery head of 10 m (1 bar).
- The wat er temperatur e
Tmax.
should not e xceed 35° C .
- Fasten the U V-C unit by means of t he fi xing stands (15) in a fl ood-proof position.
- The quar tz glass tube (2) will be polluted by the pond wat er , thus reducing the UV - C per formance .
This needs cleaning of the quartz glass tube (2) at regular intervals according to the degree of pollution.
- The UV-C lamp (1) has a rated lif e of approx . 8000 hours. Af ter tha t it should be replaced, at least a t the
end of one season (from March till October).
- We recommend you to run t he unit 24 hours a day (continuous use). A void frequent switching (on/off).
This will reduce the lifet ime of the UV-C lamp.
- Connect the translucent connections of the UV -C unit to your fi ltration sy stem (hoses, pumps, fi lt ers…).
Y ou should use only fl at gask et rings for sealing your hose connectors, joining rings or se aling liquids may
damage the threaded connection.
- The c onnections may be turned against each o ther . For this purpose you should loosen and remo ve the
union nuts (11) of the red end caps (9) and slightly loosen the pressur e plates (6) as w ell (see fi g. C).
Cleaning and changing the lamp UV-C 8 - 55 W (see fi g. C)
Dismantling
1. Follow the safe ty measures.
2. Disconnect the UV-C unit and secure against reclosing.
3. Pour out the wat er c ompletely .
4. Loosen the t wo union nuts (11) of the red end caps (9) and dra w of f both pieces.
5. Remove the lampholders (3) fr om the UV - C lamp (1).
6. Pull the UV-C lamp (1) out with caution and replace it, if necessary . Old lamps should not be brok en
and disposed of in t he household refuse. Ple ase c ontact your local company re sponsible for refuse
collection.
7. T urn out the pressure plat es (6) and draw the O -rings (7) from the quartz glass tube (2).
8. Remove the quartz glass tube (2) carefully and clean it thoroughly . Do avoid using any sharp
instruments . If the quar tz glass tube (2) or the O -rings (7) are damaged, the y should be replaced.
Assembly UV-C 8 - 55 W
9. Carefully insert the quar tz glass tube (2) into the casing and push the two O-rings (7) uniformly .
10. Tighten the two pressure plates (6).
11. Put the UV-C unit into operat ion (c onnect the pump), make the w ater circulate and check the pr essure
pla tes in order to see whether the unit is w ater -proof . Do assemble only wat erproof units completely and
connect these t o the mains supply .
12. Inser t the UV - C lamp (1) carefully into the quartz glass tube (2).
13. Put the lampholders (3) onto the lamp sockets . On one side there is the star ter sock et (4) with
starter (5) at t he back of the lampholder (3).
14. Care about the O-ring (8) at the pressure plat e (6).
15. Put on the red end caps (9) and tighten the union nuts (11).
Lamp replacement UV-C 7 5 W (see Fig. D)
1. Comply with safety measures.
2. Disconnect UV-C clarifi er from the mains supply and safeguard it from being switched on again.
3. Unscrew the cap nuts (11) on the red end caps (9A + 9B) and pull off the parts.
4. Pull the lamp socket (3) off of the UV - C lamp (1).
5. Carefully take out t he UV - C lamp (1) in direction 9B, and if necessary replace it with a new lamp.
Old UV - C lamps must not be brok en, and they must be disposed of in y our household waste.
Please contact your w aste disposal authority or company .
6. Carefully slide the UV -C lamp (1) into the quar tz glass tube (2).
7. Fit the lamp socket (3) onto t he UV - C lamp (1). The starter socket (4) with the starter (5) is behind the
lamp socket (3).
8. Fit on the red end caps (9A + 9B) and screw on the cap nuts (11) tightly . P ay attention t o the O-ring (8)!
Cleaning the UV-C 7 5 W (see Fig. D)
1. Open the UV - C clarifi er as described in points 1-5 (lamp replacement and take out t he UV C lamp (1).
2. Let the w ater completely run out of the U V-C clarifi er .
3. Unscrew pressure pieces (6A + 6B with lamp holder 6C) and pull the O-rings (7) off of the quar tz glass
tube (2).
4. Care fully pull the quart z glass tube (2) out of the housing and clean it thoroughly . Do not use any
sharp-edged tools. If the quartz glass tube (2) or the O -rings (7) are defectiv e, they must be r eplaced.
Installation UV-C 7 5 W
6. Carefully introduce the quartz glass tube (2) into the housing and slide on both two O -rings (7) uniformly .
7. Firmly screw in the pressure piece (6B).
8. Firmly screw in pr essure piece (6A with bulb socket 6C).
9. Place the UV - C clarifi er in service (connect the pump), let the wat er circulate and ex amine the pressure
pieces to check whether the de vic e is sealed. Only install complet e devices and connect them to the
mains supply if they ar e wat ertight.
10. Carefully slide UV -C lamp (1) into the quar tz glass tube (2).
11. Fit on the red end cap (9B) and screw on the cap nut (11) tightly . P ay attention t o the O-ring (8) on the
pressure piece (6B).
12. Fit the lamp socket (3) onto t he UV - C lamp (1). The starter socket (4) with the starter (5) is behind the
lamp socket (3).
13. Fit on the red end cap (9A) and screw on the cap nut (11) tightly . Pay a ttention to the O-ring (8) on the
pressure piece (6A).
T aking care of your UV -C unit in winter
Protect your UV -C unit from freezing-in!
Empty , dismount and clean the unit thoroughly in autumn.
Store it in a non-fr eezing r oom during the winter months.