658080
11
Zoom out
Zoom in
Vorherige Seite
1/49
Nächste Seite
11
ENGLISH
1. Pump Overview.........................10
2. Please Read First!.....................11
3. Range of Application and
Pumping Media .........................11
4. Safety .........................................11
4.1 Specified Conditions of Use........11
4.2 General Safety Instructions ........11
5. Prior to Operation .....................12
5.1 Installation...................................12
5.2 Connecting the Suction Line.......12
5.3 Discharge Port............................12
5.4 Connection to a Pipe System .....12
5.5 Connection to AC Power ............12
5.6 Filling the pump and priming.......12
6. Operation...................................12
6.1 Commissioning ...........................13
7. Care and Maintenance..............13
7.1 Danger of Ffreezing....................13
7.2 Pump Dismounting and
Storing ........................................13
8. Trouble Shooting......................13
8.1 Locating the Fault .......................13
8.2 Adjusting the Pressure Switch ....13
8.3 Increasing the Precharge
Pressure .....................................14
9. Repairs.......................................14
10. Environmental Protection........14
11. Available Accessories.........14/49
12. Technical Specifications..........15
These operating instructions have been
written to make it easier for you, the
operator, to learn how to operate this
pump and to do so safely. These instruc-
tions should be used as follows:
Read these instructions before use.
When reading these instructions,
pay special attention to all safety
instructions.
These operating instructions are
intended for people with basic tech-
nical knowledge regarding the oper-
ation of a pump like this or similar
pumps. Inexperienced persons are
advised to seek competent advise
from an experienced person before
operating this pump.
Keep all documents supplied with
the pump for future reference.
Retain proof of purchase for possi-
ble warranty claims.
This pump must not be sold or lent
to someone else without being
accompanied by these operating
instructions and all other machine
documents supplied with the pump.
The manufacturer assumes no liabil-
ity for any damage resulting from the
non-observance of any operating or
safety instructions given in this man-
ual.
The information in these instructions is
denoted as under:
Danger!
Risk of personal injury or
damage to the environ-
ment.
Risk of electric shock!
Risk of personal injury
by electric shock.
Caution!
Risk of material damage
Note:
Additional information.
Numbers in illustrations (1, 2, 3, ...)
indicate component parts;
are consecutively numbered;
refer to the corresponding num-
bers in brackets (1), (2), (3) ... in
the neighbouring text.
Instructions to be carried out in
sequence are numbered.
Instructions which can be carried
out in any sequence are preceded
by a bullet (•).
Listing are preceded by a dash (–).
This pump is intended for pumping clear
water in domestic applications, such as
irrigation,
well, rain and service water pump-
ing,
draining of pools, garden ponds and
water tanks.
The max. permissible temperature of the
pumped medium is 35 °C.
4.1 Specified Conditions of
Use
This pump must not be used to supply
drinking water or for pumping foodstuff.
Explosive, flammable, aggressive fluids
or substances detrimental to health as
well as salt water must not be pumped.
This pump is not suitable for commercial
or industrial use.
Modification of the pump or use of parts
not approved by the manufacturer is not
permitted.
Any use other than the use specified
above may cause unforeseeable dan-
ger!
4.2 General Safety Instruc-
tions
Children, juveniles and persons not fam-
ilar with the instructions are not permit-
ted to operate the pump.
When used in swimming pools and gar-
den ponds and within their range of pro-
tection, the regulations of DIN VDE 0100
-702, -738 or applicable local regulation
must be observed.
When used as domestic water supply
any applicable local regulations pertain-
ing to water supply and waste water dis-
posal, plus DIN 1988 (where applicable)
have to be observed.
The following residual risks do principally
exist when operating pumps and pres-
sure vessels and can not be fully elimi-
nated – even by employing safety
devices.
A
Hazard generated by ambient
conditions!
x Do not expose to rain. Do not oper-
ate in damp or wet environment.
x Do not use the pump in hazardous
locations or near inflammable liquids
and gases!
B
Danger! Risk of electric shock!
x Do not direct water jet directly
against the pump or other electrical
parts! Risk of fatal electric shock!
x Do not touch the plug with wet
hands! To unplug always pull on the
plug, not the power cable.
x The earthed outlet or the plug con-
nection to an extension cable must
be located in an area safe against
flooding.
x Use only extension cables of suffi-
cient lead cross section (see
"Technical Specifications"). Com-
pletely unroll cable reels.
x Do not buckle, squeeze, drag or
drive over power cable and exten-
sion cables; protect from sharp
edges.
x Place extension cable so that it can
not get into the fluid to be pumped.
x Unplug:
prior to all servicing;
when persons are in the swim-
ming pool or garden pond.
A
Danger by pump failures!
x If you notice transport damage while
unpacking, notify your supplier
immediately. Do not operate the
pump!
Table of Contents
2. Please Read First!
3. Range of Application and
Pumping Media
4. Safety
11

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

metabo-hww-3000-20g

Suche zurücksetzen

  • Der Wasserdruck steht auf 3 ich möchte aber einen höheren Wasserdruck haben.
    Ich denke dabei an einen Druck von 4. wie bekomme ich das hin? Was muß ich tun, bzw. beachten? Eingereicht am 30-6-2019 19:57

    Antworten Frage melden
  • Wie hoch soll der Luftdruck in der Speicherblase sein? Eingereicht am 19-4-2019 14:12

    Antworten Frage melden
  • Wie arbeitet das Hauswasserwerk Metabo 3000/20-G
    Eingereicht am 20-1-2018 20:01

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo HWW 3000-20G wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info