600803
10
Zoom out
Zoom in
Vorherige Seite
1/64
Nächste Seite
ENGLISHen
10
The pump can be switched on/off in "Mode A"
using the button (4) also. Dry-running protection is
also the same as in normal mode.
Automatic domestic water system
(device designation HWA...)
Functional principle: The device switches on when
the removal of water causes the water pressure to
fall below the switch-on pressure; it switches off
again when switch-off pressure is reached.
1. Insert mains plug.
2. Fill pump if necessary - see section .6.7
3. Switch on the device - see section 7.1).
4. Open the discharge line (open water tap or
spray nozzle).
5. Check that water emerges! The device is now
ready for operation.
Domestic water system
(device designation HWW...)
Functional principle: The device switches on when
the removal of water causes the water pressure to
fall below the switch-on pressure; it switches off
again when switch-off pressure is reached. The
pressure vessel contains a rubber bellows, which
is under air pressure (pilot pressure) when deliv-
ered; this permits the removal of small volumes of
water without the pump starting up.
1. Insert mains plug.
2. Fill pump if necessary - see section 6.7.
3. Switch on the device - see section 7.1).
4. Open the discharge line (open water tap or
spray nozzle).
5. Check that water emerges! The device is now
ready for operation.
Danger! Prior to all servicing:
-Unplug mains cable.
- Ensure that the device and connected accesso-
ries are depressurised.
- Repair and maintenance work other than
described in this section should only be carried
out by qualified specialists.
8.1 Regular maintenance
- Check device and accessories, in particular,
electrical and pressurised components, for
damage and repair if necessary.
- Check suction and discharge lines for leaks.
- If the conveying capacity decreases, clean intake
filter and filter element (if installed) and replace if
necessary.
- Check the pilot pressure of the pressure vessel
(7) (depending on features) and increase it if
necessary (see section 9.4 Increasing pilot pres-
sure).
8.2 Cleaning the intake filter (depending on
features)
1. Unscrew the cover (16) (using the key if neces-
sary (15)).
2. Pull the filter unit (17) upwards vertically to
remove.
3. Disassemble the filter unit: Hold the cup (18),
turn the filter (19) in a clockwise direction and
remove it from the cup (bayonet lock).
4. Place the cup (18) under flowing water to clean
and use a soft brush to clean the filter (19).
5. Assemble again in reverse order. In doing so,
ensure that the filter unit (17) is fully inserted.
8.3 Danger of frost
Caution! Frost (< 4 °C) destroys the pump
and accessories as both always contain
water!
- If there is a danger of frost, disassemble pump
and accessories and store in frost-free condi-
tions (see following section).
8.4 Removing and storing device
- Switch off appliance. Unplug mains cable.
- Open the discharge line (open water tap or spray
nozzle), allow water to drain off completely.
- Completely drain the pump (6) and vessel (7) by:
- unscrewing the water drain screw (9).
- Remove suction and discharge lines from
device.
- Store device in a frost-free room (min. 5 °C).
f
Danger!
- Prior to all servicing:
- Unplug mains cable.
- Ensure that the device and connected accesso-
ries are depressurised.
9.1 Pump is not running
No mains voltage.
- Check on/off switch, cables, plug, socket and
mains fuse.
Mains voltage too low.
- Use an extension cable with sufficient
conductor diameter.
Motor overheated; motor protection relay
tripped.
- After cooling the pump will switch on again.
- Guarantee sufficient ventilation, keep air slots
free.
- Observe maximum supply temperature.
Motor hums, but does not start.
- With the motor switched off, insert a screw-
driver or similar object through the air slots on
the motor and turn the fan impeller.
Pump clogged or defective.
- Disassemble and clean pump. Clean diffuser,
replace if necessary. Clean impeller, replace
if necessary. See section 11.
9.2 Pump not drawing in correctly or run-
ning very loudly:
Insufficient water.
- Ensure there is a sufficient water supply.
Pump not sufficiently filled with water.
-See section 6.7.
Suction line leaking.
- Seal suction line, tighten screw-couplings.
Suction height too high.
- Observe maximum suction height.
- Insert check valve, fill suction line with water.
Intake filter (accessories) obstructed.
- Clean, replace if necessary.
Check valve (accessories) blocked.
- Clean, replace if necessary.
Water discharge between motor and pump,
shaft seal leaking. (Minor discharge of water
(max. approx. 30 drops per day) is normal with
the use of shaft seals).
- Replace shaft seal. See section 11.
Pump clogged or defective.
-See section 9.1.
9.3 Pressure too low or pump runs continu-
ously:
Suction line leaking or suction height too high.
-See section 9.2.
Pump clogged or defective.
-See section 9.1.
HWW...: Pressure switch incorrectly adjusted.
- Read off switch-on and switch-off pressure at
the pressure gauge (11) and check values
(see section 13 Technical Specifications). If
an adjustment is necessary, please contact
Metabo Customer Service. See section 11.
HWW...: Pump starts up even after removal of
small volume of water (approx. 0.5 l).
- Check whether the pilot pressure in the pres-
sure vessel is too low. Increase pressure if
necessary. See section 9.4.
HWW...: Water is running out of the air valve.
- Rubber bellows in pressure vessel leaking,
replace it. See section 11.
P 6000 Inox: The LED (3) lights up in blue.
- "Mode A" is enabled. See section 7.2
9.4 Increasing pilot pressure (only HWW...)
If – in the course of time – the pump starts up even
after the removal of a small volume of water
(approx. 0.5 l), the pilot pressure in the vessel must
be restored.
Note:
The pilot pressure cannot be read off at the
pressure gauge (11).
1. Unplug mains cable.
2. Open the discharge line (open water tap or
spray nozzle), allow water to drain off
completely.
3. Unscrew plastic cap on front face of pressure
vessel; the air valve is located behind it.
4. Mount air pump or compressor hose with a
"tyre valve" connection and pressure gauge on
the air valve.
5. Pump up to the specified pilot pressure (see
section 13. Technical Specifications).
6. Connect device again and check operation.
f
Use only genuine Metabo accessories.
Use only accessories that fulfil the requirements
and specifications listed in these operating instruc-
tions.
For a complete range of accessories, see
www.metabo.com or the catalogue.
Danger! Repairs to this device must be
carried out by qualified electricians only!
If you have Metabo devices that require repairs,
please contact your Metabo service centre. For
addresses see www.metabo.com.
For shipment: drain pump and vessel completely
(see section 8.4).
You can download spare parts lists from
www.metabo.com.
Observe national regulations on environmentally
compatible disposal and on the recycling of
disused machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recy-
cling.
Explanatory notes on the specifications on page 3.
Subject to change in line with technological
advances.
The pump characteristic curve (diagram on page
3) shows the conveying capacity that can be
reached depending on the conveying height
(suction height 0.5 m and 1" suction hose).
V =Check valve (20) integrated at pump
suction connection (12)
K =Mains connection lead
U=Mains voltage
f=Frequency
P
1
=Rated power
I=Rated current
C =Operating condenser
n=Rated speed
F
V,max
=Max. conveying capacity
F
h,max
=Max. conveying height
F
p,max
=Max. conveying pressure
p
1
=Pressure switch: switch-on pressure
p
2
=Pressure switch: switch-off pressure
S
h,max
=Max. suction height
S
temp
=Max. supply temperature
T
temp
=Ambient temperature
S
1
=Splash protection class
S
2
=Protection class
S
3
=Insulation class
M
P
=Pump housing material
M
R
=Pump shaft material
M
W
=Pump impeller material
D
s
=Suction connection female thread
D
p
=Pressure connection female thread
T
V
=Pressure vessel volume
T
p,max
=Max. vessel pressure
T
p,1
=Vessel pilot pressure
A =Dimensions:
Length x Width x Height
m =Weight (with mains cable)
~ Alternating current
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
8. Maintenance
9. Troubleshooting
10. Accessories
11. Repairs
12. Environmental Protection
13. Technical Specifications
10

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln
1

Forum

metabo-hww-4500-25-inox

Suche zurücksetzen

  • Pumpen hat angesaugt hat ca 300 lt gepumpt und nach 2 Tagen springt sie nicht wieder an an
    Eingereicht am 16-4-2023 16:13

    Antworten Frage melden
  • Wo ist bei meiner HWW 4500 die Möglichkeit die Pumpe vor dem Winter zu entleeren. Es muss doch ein Ablassventil geben Die hauptmenge ist per Schlauch entleert. Eingereicht am 13-11-2022 16:11

    Antworten Frage melden
  • Mit wieviel Wasser muss die 4500/25 Inox befüllt werden? Eingereicht am 1-5-2022 17:49

    Antworten Frage melden
  • Mein HWW 6000/50 Inox lässt sich nicht mehr einschalten. Vor dem Winter habe ich die Pumpe vom Strom genommen. Nachdem ich vor 1 Woche den Stecker wieder in die Steckdose gesteckt habe, hat das Einschalten zunächst nicht funktioniert. Keine der LED-Kontrollleuchten ist angegangen. Erst am nächsten Tag ging es wieder.
    Jetzt hat die Pumpe sich offensichtlich wieder von alleine abgeschaltet und lässt sich wieder nicht einschalten. Keine LED leuchtet. Steckdose habe ich überprüft, Strom ist vorhanden. Was kann das für ein Fehler sein?? Eingereicht am 27-4-2022 19:58

    Antworten Frage melden
  • Unsere Pumpe arbeitet nur stoßweise. Woran kann das liegen? Kann ich das selber beheben? Eingereicht am 3-11-2021 06:48

    Antworten Frage melden
  • kann man bei einer hww 4500/25 inox den abstelldruck verändern Eingereicht am 20-7-2021 12:42

    Antworten Frage melden
  • anschlüsse wie gross sind die beim Wasser austritt Eingereicht am 18-5-2021 13:38

    Antworten Frage melden
  • Wo stelle Ich den Druck ein Punpe geht ständig an und aus ? Eingereicht am 29-3-2021 15:16

    Antworten Frage melden
  • MeinHWW 4500/25 Inox erreicht den Ausschalt von 3,6 bar nicht,und läuft ständig Woran kann das liegen. Bitte um Hilfe. Eingereicht am 12-9-2020 16:05

    Antworten Frage melden
  • Pumpe läuft normal aber esentsteht kein Druck. Ich habe schon sie gefüllt mit Wasser und den Anschluft auf Dichtung geprüft, aber sie läft leer. Was kann die Ursache sein? Eingereicht am 27-6-2020 21:56

    Antworten Frage melden
  • Mein Hauswasserwerk Elektra Beckum HWW 3309/ 20 N stellt sich nicht selbststätig aus. Eingereicht am 5-7-2019 17:49

    Antworten Frage melden
  • Stecker für ein und ausschalter sind beim reinigen der pumpe abgegangen,wie sitzen sie richtig ??? Eingereicht am 9-5-2019 21:14

    Antworten Frage melden
  • Pumpe stellt sich bei kleinster Wasserentnahme mehrfach immer wieder kurz ein und aus .Und dieser Vorgang wiederhol sich 4-5 mal. Eingereicht am 4-4-2019 16:16

    Antworten Frage melden
  • Die pumpe schaltet sich oftra an und aus
    Was Sie bereits getan haben, um das Problem zu lösen. Eingereicht am 29-3-2019 20:17

    Antworten Frage melden
  • Led leuchtet grün, Pumpe ist mit Wasser gefüllt, jedoch läuft der Pumpemmotor nicht an. Pumpenmotor brummt Eingereicht am 30-8-2017 12:47

    Antworten Frage melden

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo HWW 4500-25 Inox wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info