ENGLISH
3.3 Safety devices
Safety valve
The spring safety valve (12) is incorpo-
rated into the pressure switch unit. The
safety valve opens if the max. permissi-
ble pressure is exceeded.
4.1 Mains connection
B
Danger! High voltage
Operate device in dry environ-
ment only.
Operate device only on a power
source complying with the following
requirements:
outlets properly installed, earthed
and tested;
fuse protection in accordance
with the Technical Specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the device is
switched OFF before plugging in.
Protect power cable from heat,
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
Do not stop the compressor by
unplugging, but switch OFF using the
switch.
Unplug after use.
4.2 Generating compressed air
1. Start device (13) and wait until the
max. tank pressure is reached
(compressor shuts off).
The tank pressure is indicated by
the tank pressure gauge (14).
2. Set pressure regulator (15) to
required working pressure. The cur-
rent working pressure is indicated
by the regulated pressure gauge
(16).
A
Caution!
The regulated pressure may
not be set higher than the max. work
-
ing pressure of the connected air
tools!
3. Connect air hose to compressed air
outlet (17).
4. Connect air tool.
You are now ready to work with the
air tool.
5. Switch the device OFF, if you do not
continue working immediately after
-
wards. Unplug after switching OFF.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Wait until the device has come to
a complete stop.
Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
Let the device and all air tools
and accessories used cool off.
After all servicing:
Check to see that all safety
devices are operational.
Make sure that no tools or other
parts remain on or in the device.
Repair and maintenance work other
than described in this section must
only be carried out by qualified spe
-
cialists.
5.1 Periodic maintenance
Prior to each use
Check air hoses for damage,
replace if necessary.
Check all screwed connections for
tightness, tighten if necessary.
Check power supply cable for dam-
age, if necessary have replaced by
a qualified electrician.
Every 50 operating hours
Check air intake filter (18), clean if
necessary.
Drain condensate (19).
Every 250 operating hours
Replace air filter element.
5.2 Device storage
1. Switch unit OFF and unplug.
2. Release pressure from tank and all
connected air tools.
3. Store device in such way that it can-
not be started by unauthorized per-
sons.
A
Caution!
Do not store device unpro-
tected outdoors or in damp environ-
ment. Do not lay device on its side for
transportation or storing.
A
Danger!
Prior to all servicing:
Switch Off.
Unplug.
Wait until the device has come to
a complete stop.
Ensure the device and all air tools
and accessories connected to it
are relieved from pressure.
Let the device and all air tools
and accessories used cool off.
4. Operation
12
5. Care and Maintenance
15
16
13
14
17
6. Trouble Shooting
18
19
9

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Metabo Power 260 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info