INSTALLATION MANUAL FOR ROOM
A
AIR CONDITIONER
(Split Wall-Mounted Type)
For correct installation, read this manual before starting installation.
Only trained and qualified service personnel should install, repair or service air conditioning
equipment. Users should not install the air conditioner by themselves.
All pictures are only sketches. If there is any difference between pictures in this manual and
the actual shape of the air conditioner you purchased, the actual shape shall prevail.
Installation in the following places may cause trouble. If it is unavoidable, please, consult
with the local dealer.
A place full of machine oil.
A saline place such as coast.
A place full of sulfide gas such as hot-spring resort.
Places where there are high frequency machines such as wireless equipment, welding
machine, and medical facility.
A place of special environmental conditions.
The appliance shall not be installed in the laundry.
A place, which is convenient to installation
and not exposed to a strong wind. A place
that is dry and ventilated.
A place can bear the weight of the outdoor
unit and where the outdoor unit can be held
in the horizontal position.
A place which does not allow an increase
in noise level and vibration.
A place where the operation noise and dis-
charge air do not disturb your neighbor.
A place free of a leakage of combustible
gases.
An allowable head level at the connective
piping is less than 5m and length of the
connective piping is up less than 10m.
No any obstacle which block radiat air.
Indoor Unit
Outdoor Unit
INSTALLATION PRECAUTION
A place where is no obstacle near the inlet
and outlet area.
A place which can bear the weight of the
indoor unit.
A place which allows the air filter to be
removed.
A place where the reception range is not
Exposed to direct sunlight.
A place where the connective pipe and
drain hose is easy to led out.
A place 1m or more to TV, radio instrument,
in the center of the room is perfect.
The indoor unit should be installed 2.3
meters or more above the floor.
INDOOR UNIT INSTALLATION
1
1. Run the drain hose sloping downward. Do
not install the drain hose as illustrated
below.
2. When connection extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe
Do not form a rise
Connective
pipe
Pipe holder
Pipe cover
Right piping
Left piping
Pipe cover
Drain hose
Connective
pipe
Pipe room
Ponding box
Indoor unit outline
Connective pipe
Right back piping
Left back piping
Wrapping belt
Do not put the hose
end into water
Indoor unit
1. For the left-hand and right-hand piping,
remove the rear plate bushing from the left
side of the rear plate.
Explain to clients that the pipe cover must
be kept as it may be used when relocate
the air conditioner to any other place.
2. For the left-hand and rear-left-hand piping,
install the piping as shown. Bend the conn-
ective pipe to be laid at 43mm height or
less from the wall.
3. Fix the end of the connective pipe.
(Refer to Tightening Connection in REFRI-
GRANT PIPING CONNECTION)
Connect the indoor unit first then the outdoor
unit and bend and arrange the pipe carefully.
Do not allow the piping to let out from the
back of the indoor unit.
Be careful not to let the drain hose slack.
Insulate both of the auxiliary piping.
Banding the drain hose under the auxiliary
pipe.
Do not allow the piping to let out from the
back of the indoor unit.
Wind the connective cable, drain hose and
wiring with tape securely, evenly as shown
below.
Because the condensed water from rare
of the indoor unit is gathered in ponding
box and is piped out of room. Do not put
anything else in the box.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
43
3. Piping and bandaging
1. Drainage
2. Connective pipe
CAUTION
1. Drilling A Hole and Mounting Installation Plate
2. Connective Pipe and Drainage Installation
Installation Plate and Its Dimention
Indoor unit outline
20
12cm or more
to wall 12cm or more
to wall
Left refrigerant
pipe hole 65 Right refrigerant
pipe hole 65
Installation plate
30
70
750
45
250
15cm or more to ceiling
1. Install the installation plate horizontally on stru-
ctural parts in the wall with the spaces provided
around the plate.
2. In case of brick, concrete or similar type walls,
make 6mmdia, holes in the wall. Insert clip anc-
hors for appropriate mounting screws.
3. Fix the installation plate on the wall.
1. Pass the piping through the hole in the wall.
2. Put the upper claw at the back of the indoor unit on
the upper hook of the installation plate, move the
indoor unit from side to side to see that it is securely
hooked.
3. Piping can easily be made by lifting the indoor unit
with a cushioning material between the indoor unit
and the wall. Get it out after finish piping.
4. Push the lower part of the indoor unit up on the wall,
Then move the indoor unit from side to side, up and
down to check if it is hooked securely.
1. As diagram above determine the pipe
hole position using the installation
plate, drill the pipe hole( 65mm) so it
slants slightly downward.
2. Always use a wall hole conduit when
piercing metal lath, ply wood or metal
plate.
Upper hooker
Low hooker
Cushioning
material
Installation Plate
1. Fix the installation plate.
2. Drilling a hole.
3. Indoor Unit Installation
.
.
.
...
.
.
.
.
.
.
.
.
.
.
.
.
...
.
...
.
.
.
.
.
. .
.
NOTE: At least two of A, B, C
Aspects are free from blocking.
60cm or more
Air blowing
direction
Loop the
connective
cable.
Air filter
12cm or more
12cm or more
15cm or more
10cm or more
100cm or more
3
2
1
4
C
A
B
Before installation, operate the remote
controller to determine its location in a
reception range.
Keep the remote controller at least 1m
apart from the nearest TV set or stereo
equipment.
Do not install the remote controller in a
place exposed to direct sunlight or close
to a heating source, such as a stove.
Note that the positive and negative poles
are right positions when loading batteries.
The air-conditioner can be connected only
to a supply with system impedance no
more than 0.26 ohm. In case necessary
please consult your supply authority for
system impedance information.
Part
No.
1
2
3
4
5
6
7
8
Installation plate
Mounting screw ST3.9 25-C-H
Refrigerant
pipe
Liquid side
Gas
side
Remote controller
Remote controller holder
Seal
Drain elbow
6.35
9.53
1
8
8
1
1
1
1
Name of part Qty
Parts Installation
Cautions on remote controller installation
10cm or more
60cm or more
5
6
Clip anchor
anchor bolts of out door unit installation
The outdoor unit should not be exposed to
strong wind.
Fix the outdoor unit with 10 or 8 anchor
bolts.
air outlet
air inlet
A
B
Remote controller
Mounting screw B
ST2.9x10-C-H
Remote controller
holder
12.7
10000Btu/h
9000Btu/h
Model
7000Btu/h
9000Btu/h
50Hz R22
9000Btu/h
60Hz R22
9000Btu/h
R407C
10000Btu/h
A
458
548
548
548
458
B
250
266
266
266
250
1

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea Glory Eco MSG-xxHRN2 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea Glory Eco MSG-xxHRN2

Midea Glory Eco MSG-xxHRN2 Bedienungsanleitung - Englisch - 12 seiten

Midea Glory Eco MSG-xxHRN2 Bedienungsanleitung - Holländisch - 13 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info