588603
1
Zoom out
Zoom in
1
installation manual
2
installation manual
3
installation manual
4
installation manual
5
installation manual
6
installation manual
7
installation manual
8
installation manual
Floor Standing Type
OWNER'S MANUAL
Thank you very much for purchasing our air conditioner,
Before using your air conditioner , please read this manual carefully and keep it for future reference.
INDOOR UNIT
OUTDOOR UNIT
1
2
3
4
5
6
7
8
9
Display panel
Connecting pipe
Air inlet
Drain pipe
Air outletInstallation part
Remote controller
Fig.1
All the pictures in this manual are for explanation purpose only. They may be slightly different from the air
conditioner you purchased(depend on model).The actual shape shall prevail.
NOTE
Air flow louver (at air outlet)
Air inlet (with air filter in it)
INDOOR UNIT
OUTDOOR UNIT
7
8
1
9
6
7
1
3
4
2
5
1. IMPORTANT SAFETY INFORMATION
To prevent injury to the user or other people and property
damage, the following instructions must be followed. Incorrect
operation due to ignoring of instructions may cause harm or
damage.
WARNING
Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may result in a
water leakage, electric shock, and fire.
Ask your dealer for improvement, repair, and
maintenance.
Incomplete improvement, repair, and maintenance may
result in a water leakage, electric shock, and fire.
In order to avoid electric shock, fire or injury, or if you
detect any abnormality such as smell of fire, turn off the
power supply and call your dealer for instructions.
Never let the indoor unit or the remote controller get
wet.
It may cause an electric shock or a fire.
Never press the button of the remote controller with a
hard, pointed object.
The remote controller may be damaged.
Never replace a fuse with that of wrong rated current or
other wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down
or cause a fire.
It is not good for your health to expose your body to the
air flow for a long time.
Do not insert fingers, rods or other objects into the air
inlet or outlet.
When the fan is rotating at high speed, it will cause injury.
Never use a flammable spray such as hair spray,
lacqueror paint near the unit.
It may cause a fire.
Never touch the air outlet or the horizontal blades while
the swing flap is in operation.
Fingers may become caught or the unit may break down.
Never put any objects into the air inlet or outlet.
Objects touching the fan at high speed can be dangerous.
Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.
Do not dispose this product as unsorted municipal
waste.Collection of such waste separately for special
treatment is necessar
CAUTION
Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit
for cooling precision instruments, food, plants, animals or
works of art.
Before cleaning, be sure to stop the operation, turn the
breaker off or pull out the supply cord.
Otherwise, an electric shock and injury may result.
In order to avoid electric shock or fire, make sure that an
earth leak detector is installed.
Be sure the air conditioner is grounded.
In order to avoid electric shock, make sure that the unit is
grounded and that the earth wire is not connected to gas or
water pipe, lightning conductor or telephone earth wire.
In order to avoid injury, do not remove the fan guard of
the outdoor unit.
Do not operate the air conditioner with a wet hand.
An electric shock may happen.
Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture
under the indoor unit.
Condensation may form if the humidity is above 80%, the
drain outlet is blocked or the filter is polluted.
After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency, ventilate the room
sufficiently if equipment with burner is used together
with the air conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Contact you local government for information regarding
the connection systems available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundeater and get
into the food chain, damaging your health and well-being.
To prevent refrigerant leak, contact your dealer.
When the system is installed and runs in a small room, it is
required to keep the concentration of the refrigerant, if by any
chance coming out, below the limit. Otherwise, oxygen in the
room may be affected, resulting in a serious accident.
The refrigerant in the air conditioner is safe and normally
does not leak.
If the refrigerant leaks in the room, contact with a fire of a
burner, a heater or a cooker may result in a harmful gas.
Turn off any combustible heating devices, ventilate the
room, and contact the dealer where you purchased the
unit.
Do not use the air conditioner until a service person confirms
that the portion where the refrigerant leaks is repaired.
WARNING
The safty precautions listed here are divided into two categories. In
either case, important safty information is listed which must be read
carefully.
CAUTION
Failure to observe a caution may result in injury or damage
to the equipment.
The appliance shall be installed in accordance with national
wiring regulations. Failure to observe a warning may result
in death.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence to little children, animals and plants may
result.
Do not allow a child to mount on the outdoor unit or
avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room
fumigation - type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of
those who are hypersensitive to chemicals.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
The appliance is not intended for use by young children
or infirm persons without supervision.
Young children should be supervised to ensure that they
do not play with the appliance.
2. TEMPORARY OPERATIONS
The air conditioner consists of the indoor unit, the outdoor unit,
the connecting pipe and the remote controller.
(see Fig.2-1)
Function indicators on indoor unit display panel
Fig. 2-1 Display panel
PRE-DEF indicator(cooling and heating
type)
or fan only indicator(cooling only type)
Infrared signal receiver
Operation lamp
Timer indicator
Temporary button
NOTE
This manual does not include Remote Controller
Operations, see the<<Remote Controller Owner's
manual>> packed with the unit for details.
This function is used to operate the unit temporarily in case you
misplace the remote controller or its batteries are exhausted.
Two modes including AUTO and FORCED COOL can be
selected through the TEMPORARY BUTTON on the display
panel. Once you push this button, the air conditioner will run in
such order: AUTO, FORCED COOL,(COOLING TEST
HEATING TEST,)OFF, and back to AUTO.
AUTO
The OPERATION lamp is lit, and the air conditioner will run
under AUTO mode. The remote controller operation is enabled
to operate according to the received signal.
FORCED COOL
The air conditioner will turn to AUTO after it is enforced to cool
with a wind speed of LOW for 30 minutes. The remote controller
operation is disabled.
COOLING TEST
Partial units have this function.
The function just be used during test and maintenance.
HEATING TEST
Partial units have this function.
The function just be used during test and maintenance.
OFF
The OPERATION lamp goes off. The air conditioner is OFF
while the remote controller operation is enabled.
1
2
3
4
5
Use the system in the following temperature for safe and
effective operation.The Max operation temperature for
the air conditioner.(Cooling/Heating)
3. AIR CONDITIONER OPERATIONS AND
PERFORMANCE
Cooling operation
Dry operation
Heating operating
(cooling only
type without)
Temperature
Outdoor
temperature
Room
temperature
21 43
-5 24
0 30
17 32
11 43 17 30
1 If air conditioner is used outside the above conditions, it may
cause the unit to function abnormally.
Room relative humidity should be less than 80%. If the air
conditioner is over it , the surface of the air conditioner may
condense water . Please set the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH speed.
Optimum performance will be achieved within these
operating temperature range.
2
3
NOTE
Fig. 5-1
Fig. 5-2 Fig. 5-3
4. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical operation.
(Refer to corresponding chapterfor details)
5. ADJUSTING AIR FLOW DIRECTION
Auto-swing
Press SWING button, the louver will swing up and down
automatically.
When cooling
Adjust the louver downwards. (vertically)(see Fig. 5-2).
When heating
Adjust the louver horizontally(see Fig.5-3)
Three-minute protection feature
A protection feature prevents the air conditioner from being
activated for approximately 3 minutes when it restarts immedi-
ately after operation.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp on the indoor unit will start
flashing when power is restored.
To restart operation, push the ON/OFF button on the
remote controller.
Lightning or a car wireless telephone operating nearby
may cause the unit to malfunction.
Disconnect the unit with the power and then connect the unit
with the power again. Push the ON/OFF button on the remote
controller to restart operation.
Adjust the air flow direction properly to avoid winding toward
your body.
Adjust the room temperature properly to get a comfortable
situation and to avoid supercooling and superheat.
In cooling, close the curtains to avoid direct sunlight.
To keep cool or warm air in the room, never open doors or
windows more often than necessary.
Set the timer for the desired operating time.
Never put obstructions near the air outlet or the air inlet. Or it
will cause lower efficiency, even a sudden stop.
If you don't plan to use the unit for a long time, please discon-
nect power and remove the batteries from the remote control-
ler. When the power switch is connected, some energy will be
consumed, even if the air conditioner isn't in operation. So
please disconnect the power to save energy. And please
switch the power on 12 hours before you restart the unit to
ensure a smooth operation.
A clogged air filter will reduce cooling or heating efficiency,
please clean it once two weeks.
Manual Swing
Press Air Direction button,the louver can be fixed at a desir-
ed angle.The louber swing (upward or downward ) to a
certain angle for each press.
Adjust the Air Flow Direction Left and Right
Hold the knob and move the louver.
You will find a knob one the left-side and the right-side
blades.(see Fig.5-4)
7. MAINTENANCE
Maintenance after a long stop period
(eg. at the beginning of the season)
Maintenance before a long stop period
(eg. at the end of the season)
Check and remove everything that might be blocking inlet
and outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how to
proceed and make sure to install cleaned air filters back in
the same position.
Turn on the power at least 12 hours before operating the
unit in order to ensure smoother operation. As soon as he
power is turned on, the remote controller displays appear.
Let the indoor units run in fan only operation for about half
a day in order to dry the interior of the units.
Clean air filters and casings of indoor units. Refer to "
Cleaning the air filter" for details on how to proceed and
make sure to install cleaned air filters back in the same
position.
Cleaning the air filter
The air filter can prevent the dust or other particulate from
going inside .In case of blockage of the filter , the working
efficiency of the air conditioner may greatly decrease .
Therefore , the filter must be cleaned once two weeks
during long time usage.
If the air conditioner is installed in a dust place , clean the
the air filter frequent.
If the accumulated dust is too heavy to be cleaned , please
replace the filter with a new one(replaceable air filter is an
optional fitting).
CAUTION
Before you clean the air conditioner, be sure the power
supply is off.
Check if the wiring is not broken off or disconnected.
Use a dry cloth to wipe the indoor unit and remote
controller.
A wet cloth may be used to clean the indoor unit if it is
very dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treted duster for wiping or leave
such material on the unit for long.
it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar
solvents for cleaning.
These may cause the plastic surface to crack or deform.
Fig. 5-4
CAUTION
Before opening the front panel,be sure to stop the
operation and turn the breaker OFF.
Do not touch the metal parts on the inside of the indoor
unit,as it may result in injury.
6. AIR FLOW SELECTION
Open the front panel.
How to open the front panel:(see Fig. 7-1).
Make air flow selection according to what suits you.
(Pleas refor to Fig. 7-2 about the position of)
When setting the air flow selection switch to .
Air conditioner automatically decides the appropriate blowing
pattern depending on the operating mode/situation.
During Dry mode,so that cold air does not come into direct
contact with people,air is blown upper air outlet.
Regardless of the operating mode or situation,air blows from
the upper air outlet.
Use this switch when you do not want air coming out of the
lower air outlet.(While sleeping stc.)
Operating
mode
Situation
Blowing
pattern
COOL mode HEAT mode
When the room
has become fully
cool,or when one
hour has passed
since turning on
the air condition-
er.
So that air does
not come into dir-
ect contact with
people,air is blo-
wn upper air ou-
tlet,room tempe-
rature is equaliz-
ed.
At start of
operation or
other times
when the
room is not
fully cooled.
At times other than below.(
Normal time.)
Air is blown from the
upper and lower air
outlets for high spe-
ed cooling during
COOL mode,and for
filling the room with
warm air during
HEAT mode.
At start or when
air temoerature
is low.
So that air does
not come into
direct contact
with people.Air
is blown upper
air outlet.
When setting the air outlet selection switch to .
7. MAINTENANCE
Maintenance after a long stop period
(eg. at the beginning of the season)
Maintenance before a long stop period
(eg. at the end of the season)
Check and remove everything that might be blocking inlet
and outlet vents of indoor units and outdoor units.
Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how to
proceed and make sure to install cleaned air filters back in
the same position.
Turn on the power at least 12 hours before operating the
unit in order to ensure smoother operation. As soon as he
power is turned on, the remote controller displays appear.
Let the indoor units run in fan only operation for about half
a day in order to dry the interior of the units.
Clean air filters and casings of indoor units. Refer to "
Cleaning the air filter" for details on how to proceed and
make sure to install cleaned air filters back in the same
position.
Cleaning the air filter
The air filter can prevent the dust or other particulate from
going inside .In case of blockage of the filter , the working
efficiency of the air conditioner may greatly decrease .
Therefore , the filter must be cleaned once two weeks
during long time usage.
If the air conditioner is installed in a dust place , clean the
the air filter frequent.
If the accumulated dust is too heavy to be cleaned , please
replace the filter with a new one(replaceable air filter is an
optional fitting).
CAUTION
Before you clean the air conditioner, be sure the power
supply is off.
Check if the wiring is not broken off or disconnected.
Use a dry cloth to wipe the indoor unit and remote
controller.
A wet cloth may be used to clean the indoor unit if it is
very dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treted duster for wiping or leave
such material on the unit for long.
it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar
solvents for cleaning.
These may cause the plastic surface to crack or deform.
Fig.7-1
Fig.7-2
CAUTION
Do not dry out the air filter under direct sunshine or with fire.
Open the front panel.(see Fig. 7-1)
1
Remove the air filter.2
Clean the air filter
Vacuum cleaner or pure water may be used to clean the air
filter.If the dust accumulation is too heavy , please use soft
brush and mild detergent to clean it and dry out in cool place
The air-in side should face up when using vacuum cleaner.
(See Fig. 7-4)
The air-in side should face down when using water.
(See Fig. 7-5)
Press the claws on the right and left of the air filter down slig-
htly,then pull upward.(see Fig. 7-2)
Take off the especial function filter3
Hold the tabs of the frame,and remove the claws in 4 places.
(see Fig. 7-3 )
(The especial function filter can be renewed by washing it
with water once every 6 months.We recommend replacing it
once every 3 years.)
Set the air filter and the especial function filter as they were
and close the front panel.
5
Operation without air filters may result in troubles as dust will
accumulate inside the indoor unit.
4
Fig.7-3
Fig.7-4
Fig.7-5
Air Outlet
Selection Switch
especial function filter
8. FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES
Symptom 1: The system does not operate
Symptom 2: Change into the fan mode during
cooling mode
Symptom 3: White mist comes out of a unit
Sptom 4: Noise of air conditionerscooling
The air conditioner does not start immediately after the ON/OFF
button on the romote controller is pressed.
If the operation lamp lights, the system is in normal condition.To
prevent overloading of the compressor motor, the air
conditioner starts 3 minutes after it is turned ON.
If the operation lamp and the "PRE-DEF indicator(cooling and
heating type) or fan only indicator(cooling only type)" light, it
means you choose the heating model, When just starting, if the
compressor has not started, the indoor unit appears "anti cold
wind" protection because of its overlow outlet temperature.
In order to prevent the indoor evaporator frosting, the system
will change into fan mode automatically, restore to the cooling
mode after soon.
When the room temperature drops to the set temperature, the
compressor goes off and the indoor unit changes to fan mode;
when the temperature rises up, the compressor starts again. It
is same in the heating mode.
Symptom 3.1: Indoor unit
Symptom 3.2: Indoor unit, outdoor unit
Symptom 4.1: Indoor unit
When humidity is high during cooling operation If the interior of
an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to
clean the interior of the indoor unit. Ask your dealer for details
on cleaning the unit. This operation requires a qualified service
erson
When the system is changed over to heating operation after
defrost operation Moisture generated by defrost becomes
steam and is exhausted.
A continuous low "shah" sound is heard when the system is in
cooling operation or at a stop.
When the drain pump (optional accessories) is in operation,this
noise is heard.
A "pishi-pishi" squeaking sound is heard when the system stops
after heating operation.
Expansion and contraction of plastic parts caused by
temperature change make this noise.
Symptom 4.2: Indoor unit, outdoor unit
A continuous low hissing sound is heard when the system is in
operation.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.
A hissing sound which is heard at the start or immediately after
stopping operation or defrost operation.
This is the noise of refrigerant caused by flow stop or flow
change.
Symptom 4.3: Outdoor unit
When the tone of operating noise changes.
This noise is caused by the change of frequency.
.
Symptom 5: Dust comes out of the unit
Symptom 6: The units can give off odours
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.
Symptom 7: The outdoor unit fan does not
spin.
During operation. The speed of the fan is controlled in order to
optimize product operation.
The operation lamp is flashing rapidly (50Hz) This lamp is still
flashing rapidly after turn off the power and turn on again.(see
in Table 9-1)
Remote controller receives malfunction or the button does not
work well.
A safety device such as a fuse, a breaker frequently actuates.
Obstacles and water enter the unit.
Water leaks from indoor unit.
Other malfunctions.
9. TROUBLESHOOTING
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures. (see in Table 9-2)
9.1. Troubles and causes of air conditioner
Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air
smooth.
Close doors and windows.
Make curtains in order to shelter from
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage and rightly recharge
refrigerant.
Air flowing normally but
completely can't cooling
Units start or stop frequently
Low cooling effect
Low heating effect
Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not set correctly.
Be in 3 minutes protection of
compressor.
Refrigerant is too little or too much.
Air or no concretingc gas in the
refrigerating circuit.
Compressor is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Outdoor unit and indoor unit heat
exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor/outdoor units is
blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Outdoor temp. is too high.
Leakage of refrigerant or lack of
refrigerant.
Wait for the comeback of power.
Switch on the power.
ReplLocation:
Replace the batterises or check the
controller.
Set the temperature properly.
Wait.
Check leakage, and rightly recharge
refrigerant.
Vacuum and recharge refrigerant.
Maintenance or change compressor.
Install manostat.
Find reasons and solution.
Use heating device.
Close doors and windows.
Check leakage and rightly recharge
refrigerant.
Outdoor temperature is lower than 7 C
Doors and windows not completely
closed.
Leakage of refrigerant or lack of
refrigerant.
SolutionSymptoms Causes
Unit does not start
Table 9-2
Table 9-1
(× Extinguish, Flash at 50Hz
NO.
Malfunction running lamp timer lamp defrosting lamp
1
2
3
4
Room temperature sensor
checking channel is abnormal
Evaporator sensor checking
channel is abnormal
Condenser sensor checking
channel is abnormal
Room Circuit malfunction
×
×
×
××
×
9.3 Troubles and causes of remote controller
Before asking for serving or repairing , check the following points.
(see in Table 9-3)
Symptoms
Causes
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner will
automatically change the fan
speed.
When dry operation is selected,
the air conditioner automatically
change the fan speed. The fan
speed can be selected during
"COOL" , "FAN ONLY", and "HEAT"
The remote controller signal is
not transmitted even when
the ON/OFF button is pushed.
Check whether the batteries
in the remote controller are
exhausted.
The power supply is off.
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pressed.
Check whether the signal
transmitter of the remote
controller is properly directed
to the infrared signal receiver
of the indoor unit when the
ON/OFF button is pressed.
Directly transmit the signal transmitter of
the remote controller to the
infrared signal receiver of the
indoor unit, and then repeatly
push the ON/OFF button twice.
The indication on the display
disappears after a lapse of
time.
Check whether the timer
operation has come to an
end when the TIMER OFF
is indicated on the display.
The air conditioner operation will
stop up to the set time
The TIMER ON indicator
goes off after a lapse of
certain time.
Check whether the timer
operation is started when
the TIMER ON is indicated
on the display.
Up to the set time, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The TEMP. indicator does
not come on.
Check whether the MODE
indicated on the display is
FAN ONLY
The temperature cannot be set during
FAN mode.
Table 9-3
Solution
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.cn

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea MFA-12HRDN1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea MFA-12HRDN1

Midea MFA-12HRDN1 Installationsanweisung - Englisch - 24 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info