Before using your air conditioner, please read
this manual carefully and keep it for future reference.
ROOM AIR CONDITIONER
Please read this installation manual completely
before installing the product.
If the power cord is damaged, replacement work
shall be performed by authorised personnel only.
Installation work must be performed in accordance
with the national wiring Standards by authorised
personnel only.
Contact an authorised service technician for
repair, maintenance or installation of this unit.
INVERTER ONE-TWO / ONE-THREE
/ONE- FOUR SPLIT-TYPE
3
Selecting installation place
Read completely, then follow step by step.
Indoor unit
Do not expose the indoor unit to heat or steam.
Select a place where there are no obstacles
in front or around the unit.
Make sure that condensation drainage can
be conveniently routed away.
Do not install near a doorway.
Ensure that the space on the left and right
of the unit is more than 12cm.
Use a stud finder to locate studs to prevent unnecessary damage to the wall.
The indoor unit should be installed on the wall at a height of 2.0 metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling.
Any variations in pipe length will/may require adjustment to refrigerant charge.
Outdoor unit
If an awning is built over the outdoor unit to
prevent direct sunlight or rain exposure,
make sure that heat radiation from the
condenser is not restricted.
Ensure that the clearance around the back
of the unit is more than 30cm
. The front of the unit should
have more than 200cm of clearance and the
connection side (right side) should have more
than 60cm of clearance.
Do not place animals and plants in the path of the air inlet or outlet.
Take the air conditioner weight into account and select a place where noise and vibration
will not be an issue.
Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.
If the outdoor unit is installed on a roof structure, be sure to level the unit.
Ensure the roof structure and anchoring method are adequate for the unit location.
Consult local codes regarding rooftop mounting.
If the outdoor unit is installed on roof structures or external walls, this may result in
excessive noise and vibration, and may also be classed as a non serviceable installation.
and left side is
more than 30cm
Rooftop installation:
INSTALLATION INSTRUCTIONS
More than 30cm
More than 60cm
More than 30cm
More than 200cm
Fig.2
More than 2.0m
More than 15cm
More than 12cm
More than 12cm
Fig.1
4
Accessories
INSTALLATION INSTRUCTIONS
Note: Except the above parts provided, the other parts needed during installation you must
purchase.
Parts you must
purchase
(The minimum pipe
wall-thickness
of 0.7mm is required. )
6.35
9.53
12.7
8
2
Self-tapping Screw B ST2.9X10
Remote controller
Installation Plate
Name of Accessories
Self-tapping Screw A ST3.9X25
Seal (See Page 8 for details)
Drain Joint
Connecting
pipe
Assembly
Liquid side
Plastic Expansion Sheath
Number
Q ty/one unit
Gas side
9
Remote controller holder
1
( 12000Btu/h model)
( 12000Btu/h model)
(See page 8 for details)
1
8
8
1
1
1
7
6
5
4
3
2
1
Level gauge
Screwdriver
Electric drill,Hole core drill ( 65φ mm)
Flaring tool set
Specified torque wrenches: 1.8kgf.m, 4.2kgf.m,
5.5kgf.m, 6.6kgf.m(different depending on model No.)
Spanner (half union)
Hexagonal wrench (4mm)
Gas-leak detector
Tools needed for installation:
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape
This illustration is for explanation purposes only.
The actual shape of your air condtioner may be
slightly different.
Copper lines must be insulated independently
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
A minimum pipe run of 3 metres is required
to minimise vibration & excessive noise.
Two of the A, B and C directions should be
free from obstructions.
CAUTION
INSTALLATION INSTRUCTIONS
5
CAUTIONS
One-Two
One-Three
One-Four
More than 12cm
Air filter
Remote
controller
More than 12cm
Air filter
Remote
controller
Remote
controller
Air filter
More than
12cm
More than 15cm
More than
12cm
Air filter
Remote
controller
More than
10cm
A
B
C
More than 200cm
Air out
More than 60cm
More than
30cm
More than
60cm
Loop a
connective
cable
1
2
3
4
5
6
Fig.3
9
Settlement of outdoor unit
Anchor the outdoor unit with
a bolt and nut 10 or 8 tightly
and horizontally on a concrete
or rigid mount.
φφ
A
B
Air inlet
Air outlet
Air inlet
Fig.14
Install the outdoor unit on a rigid base to
prevent increasing noise level and vibration.
Determine the air outlet direction where the
discharged air is not blocked. In the case that
the installation place is exposed to strong wind
such as a seaside, make sure the fan operating
properly by putting the unit lengthwise along the
wall or using a dust or shield plates.
Specially in windy area, install the unit to prev-
ent the admission of wind. If need suspending
installation, the installation bracket should
accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick,
concrete or the same intensity construction, or
actions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
Be sure there is no obstacle which block
radiating air.
Strong
wind
Fig.13
Outdoor unit installation
Outdoor installation precaution
INSTALLATION INSTRUCTIONS
A(mm)
560
590
B(mm)
335
333
Fit the seal into the drain elbow, then insert the
drain joint into the base pan hole of outdoor unit,
rotate 90 to securely assemble them.
Connecting the drain joint with an extension drain
hose (Locally purchased), in case of the water
draining off the outdoor unit during the heating
mode.
Drain joint installation
Seal
Drain joint
Base pan hole of
outdoor unit
Seal
Drain pipe
Refrigerant pipe connection
Oblique
90 C
Roughness
Burr
Main cause for refrigerant leakage
is due to defect in the flaring work.
Carry out correct flaring work
using the following procedure:
1. Use the piping kit accessory or pipes
purchased locally.
2. Measure the distance between the indoor
and the outdoor unit.
3. Cut the pipes a little longer than the
measured distance.
4. Cut the cable 1.5m longer than the pipe
length.
A: Cut the pipes and the cable.
1. Flaring work
Fig.15
B: Burr removal
1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.
Pipe
Reamer
Point down
Fig.16
Fig.17
C: Putting nut on
Remove flare nuts attached to indoor and
outdoor unit, then put them on pipe/tube
having completed burr removal.(not possible
to put them on after flaring work)
Flare nut
Copper tube
Fig.18
10
REFRIGERANT PIPE CONNECTION
5

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea MSQ4I-07HRDN1 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea MSQ4I-07HRDN1

Midea MSQ4I-07HRDN1 Bedienungsanleitung - Englisch - 14 seiten

Midea MSQ4I-07HRDN1 Bedienungsanleitung - Holländisch - 10 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info