684504
18
Zoom out
Zoom in
Vorherige Seite
1/22
Nächste Seite
15
Installation & Owner's Manual
Table.6-1
Table.6-2
6.4 Error phenomenon shooting
Error
phenomenon
Possible reason solution
Cold water
out and
display screen
extinguished
No hot water
out
Water leakage
Hydraulic pipeline joints
are not sealed well.
Bad connection between power supply plug
and socket;
Setting water temperature too low;
Temper sensor broken ;
PCB of indicator broken ;
Compressor broken.
Plug in;
Setting water temp. higher;
Contact service center.
Waiting for public water supply recover;
Waiting for inlet water pressure increase;
Open water inlet valve.
Check and reseal all joints.
Public water supply ceased;
Cold water inlet pressure too low (<0.15 MPa);
Cold water inlet valve closed.
Malfunction Description Corrective action Display
Error of sensor T5U(upper water temperature sensor) E0
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
Error of sensor T5L(lower water temperature sensor) E1
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
Tank and Wired Controller communication error E2
Maybe the connection between controller and PCB is broken
or PCB has been broken.
Evaporator temperature sensor T3 error E4
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
ambient temperature sensor T4 error E5
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
Compressor discharge temperature sensor TP error E6
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
E8
Electric leakage error
If PCB current_induction_circuit check the current
difference between L,N >14mA, system consider it as
"electric leakage error"
Maybe some wires have been broken or bad wire
connection.
Contact a qualified person to service the unit.
Compressor suction temperature sensor TH error E9
Maybe the connection between sensor and PCB is broken
or sensor has been broken.
Contact a qualified person to service the unit.
EE
E-heater open-circuit error( IEH(Current difference
E-heater on & E-heater off )<1A)
Maybe the E-heater has been broken or bad wire
connection after repair.
Clock chip error EF
Maybe the chip has been broken, but unit can work well
without clock-menmory, so it is needed to reset clock
when power put on again.
If necessary, contact a qualified person to service the
unit.
6.5 Error code shooting table
E-EPROM chip error Contact a qualified person to service the unit.
Ed
P1
System high pressure protection
3.0MPa active
;≤
2.4MPa inactive
System blocked, air or water or more refrigerant
in system(after repair), water temperature
sensor malfunction, ect.
Contact a qualified person to service the unit.
18

Brauchen Sie Hilfe? Stellen Sie Ihre Frage.

Forenregeln

Missbrauch melden von Frage und/oder Antwort

Libble nimmt den Missbrauch seiner Dienste sehr ernst. Wir setzen uns dafür ein, derartige Missbrauchsfälle gemäß den Gesetzen Ihres Heimatlandes zu behandeln. Wenn Sie eine Meldung übermitteln, überprüfen wir Ihre Informationen und ergreifen entsprechende Maßnahmen. Wir melden uns nur dann wieder bei Ihnen, wenn wir weitere Einzelheiten wissen müssen oder weitere Informationen für Sie haben.

Art des Missbrauchs:

Zum Beispiel antisemitische Inhalte, rassistische Inhalte oder Material, das zu einer Gewalttat führen könnte.

Beispielsweise eine Kreditkartennummer, persönliche Identifikationsnummer oder unveröffentlichte Privatadresse. Beachten Sie, dass E-Mail-Adressen und der vollständige Name nicht als private Informationen angesehen werden.

Forenregeln

Um zu sinnvolle Fragen zu kommen halten Sie sich bitte an folgende Spielregeln:

Neu registrieren

Registrieren auf E - Mails für Midea RSJ-35 - 300RDN3 wenn:


Sie erhalten eine E-Mail, um sich für eine oder beide Optionen anzumelden.


Andere Handbücher von Midea RSJ-35 - 300RDN3

Midea RSJ-35 - 300RDN3 Bedienungsanleitung - Holländisch - 27 seiten


Das Handbuch wird per E-Mail gesendet. Überprüfen Sie ihre E-Mail.

Wenn Sie innerhalb von 15 Minuten keine E-Mail mit dem Handbuch erhalten haben, kann es sein, dass Sie eine falsche E-Mail-Adresse eingegeben haben oder dass Ihr ISP eine maximale Größe eingestellt hat, um E-Mails zu erhalten, die kleiner als die Größe des Handbuchs sind.

Ihre Frage wurde zu diesem Forum hinzugefügt

Möchten Sie eine E-Mail erhalten, wenn neue Antworten und Fragen veröffentlicht werden? Geben Sie bitte Ihre Email-Adresse ein.



Info